hoW To oRdeR RePlaCemenT PaRTs & TRoUbleshooTInG

PRoblem 1

Meter lockup; rotors do not turn.

PRobable CaUse a

Strainer basket rupture possibly due to improper maintenance of

the strainer basket. If this occurred in a new system, the system

may have been improperly flushed.

solUTIon a

Replace the strainer basket and follow proper strainer maintenance

procedures. New systems should be flushed. In all systems, the

meter chamber will require cleaning and may require replacement of

parts. Refer to your meter Installation, Operation and Maintenance

Manual for meter maintenance procedures or contact your full

service distributor.

PRobable CaUse b

Debris entered the metering chamber possibly due to improper

cleaning during strainer maintenance. (i.e. dirt dislodged into the

strainer housing when the basket was removed for cleaning.)

solUTIon b

Properly clean the strainer housing as outlined in the Maintenance

section of this book. The meter chamber will require cleaning and

may require replacement of parts. Refer to your meter Installation,

Operation and Maintenance Manual for meter maintenance
procedures or contact your full service distributor.

PRobable CaUse C

Denting or distortion of the strainer basket which opened gaps and

allowed foreign particles to pass through to the meter chamber.

This is usually caused by improper handling of the strainer basket

during maintenance.

solUTIon C

Replace the strainer basket and follow proper strainer maintenance

procedures. The meter chamber will require cleaning and may

require replacement of parts. Refer to your meter Installation,

Operation and Maintencance Manual for meter maintenance
procedures or contact your full service distributor.

PRoblem 2

Meter inspection due to meter inaccuracy revealed

scoring of the meter chamber.

PRobable CaUse a

See the probable causes for Problem 1.

solUTIons a

See the solutions for Problem 1. However, if inspection does

not reveal a ruptured strainer basket and it is known that proper

maintenance cleaning procedures were followed, contact your full

service distributor.

how to order Replacement Parts

1. Refer to the exploded view drawings on pages 8-15. Find the four-digit item number of the part that needs replaced. Item numbers

are listed on the exploded drawings.

2. In the red Owner’s Information Packet, you will find a computer printout titled Parts List. The Parts List lists each item number

alongside a five-digit part number. The part number identifies the specific individual piece, kit, or complete assembly used to

assemble that particular meter.

3. Contact your distributor and give them the five-digit part number. Your distributor will use it to find the correct part for your strainer.

PRoblem 3

High pressure drop across the strainer or loss of

flow rate.

PRobable CaUse a

Strainer basket screen is partially blocked by foreign material such

as dried material or salted out solid particles due to drying.

solUTIon a

Properly clean the strainer housing as outlined in the Maintenance

section. The meter chamber may require cleaning and replacement

parts. Refer to your meter Installation, Operation and Maintenance

Manual for meter maintenance procedures or contact your full

service distributor.

PRobable CaUse b

Inner mesh of the strainer basket is not properly sized for viscosity

of the product.

solUTIon b

Replace the strainer basket with a basket correctly suited for the

product.

PRoblem 4

Leaking at the strainer basket cover.

PRobable CaUse a

The seals are allowing product to leak. This is caused by a

damaged o-ring or gasket seal, or reusing a PTFE seal after

strainer maintenance.

solUTIon a

Replace the damaged seals. Replace PTFE seals if they were

reused even if they are in good condition.

PRobable CaUse b

Dirty areas that are preventing the seals from making complete

contact.

solUTIon b

Clean the strainer housing as outlined in the Maintenance section.

Remember to replace PTFE seals and never to reuse them.