Specifications – Liquid Controls AN25 User Manual

Page 2

Advertising
background image

Sponsler Co., Inc.

AN25 Totalizer/Rate Indicator

pg. 2

DOC#: MN-AN25

SPECIFICATIONS

Temperature:

Operating 0 to 70

°C

Storage -20 to 85

°C

Input Voltage:

110VAC or 12-16.5VDC 100mA MAX
Observe Polarity

Signal Input:

Frequency 0-10KHz
Amplitude 50mV – 35V sine or square wave
Sensitivity field adjustable
Impedance 10K

Display:

LCD, 8 Digit .3” characters
Totalizer – 8 Digit
Rate Indicator – 5 Digit
Leading zero blanking on rate function
Totalizer has battery backup
Totalizer reset externally initiated
Engineering units – Input factoring .00000001 – 1.9999

Accuracy:

Totalizer + 1 Count
Rate Indicator + 1%
Analog Outputs .3% F/S

Analog Output:

4mA @ 0Hz, 20mA @ desired full scale frequency
0V @ 0Hz, 5V or 10V @ desired full scale frequency
Full scale range 100Hz-10KHz
Response time 95% of change in 1 second
Linearity .3% F/S
Tempco < 2% of reading over entire temperature range
4-20mA Maximum load resistance 500 Ohms
Voltage Output minimum load resistance 250 Ohms

AN25-L:

Loop powered by a 4-20mA loop input
Minimum voltage 6.5V + (.02 x RL)
Maximum Voltage 28V + (.004 x RL)
(Same temperature, Display and accuracy specifications apply)

Enclosure:

Panel mount, ¼ DIN molded plastic

Advertising