V20080814




The earth has to be connected!
Connect the device to the mains with the power plug. If the device will be
directly connected with the local power supply network, a disconnect switch with a minimum opening of 3mm at
every pole has to be included in the permanent electrical installation.

CLEANING AND MAINTENANCE


The operator has to make sure that safety relating and machine technical installations are inspected by an expert
after every four years in the course on an acceptance test. The operator has to make sure that safety relating and
machine technical installations are inspected by a skilled person once a year.

The following points have to be considered during the inspection:

1) All screws used for installing the devices or parts of the device have to be tightly connected and must not

be corroded.

2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,

trussing).

3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or

sediments. Further instructions depending on the installation spot and usage have to be adhered to by a
skilled installer and any safety problems have to be removed.


We recommend a frequent cleaning of the device. Please use a moist, lint free cloth. Never use alcohol or
solvents! The objective lens will require weekly cleaning as smoke fluid tends to build up residues, reducing the
light output very quickly. The venting slots should be cleaned monthly. The interior of the device should be
cleaned at least annually using a vacuum cleaner or air jet. There are no serviceable parts inside the device
except for the lamp. Maintenance and service operations are only to be carried out by authorized dealers. Please
refer to the instructions under "Installing/Replacing the lamps". Should you need any spare parts, please use
genuine parts. If the power supply cable of this device becomes damaged, it must be replaced by an authorized
dealer only in order to avoid hazards. Should you have any further questions please contact your local dealer.

BEAM SIZE

10 Degree

Distance

(ft)

80 90 100 110 120

Beam

Diam.

12.8 14.4 16 17.6 19.2

19 Degree

Distance

(ft) 40 50 60 70 80

Beam

Diam.

10.8 13.5 16.2 18.9 21.6

26 Degree

Distance

(ft) 30 40 50 60 70

Beam

Diam.

9.9 13.2 16.5 19.8 23.1

36 Degree

Distance

(ft) 10 20 30 40 50

Beam Diam.

4.5

9

13.5

18

22.5

50 Degree

Distance

(ft) 10 20 30 40 50

Beam

Diam.

5.7 11.4 13.5 22.8 28.5