P a c a – Lightronics AB0302A User Manual

Page 4

Advertising
background image


Page

4

of

10

AB-0602A ARCHITECTURAL BALLAST DRIVER

Version 0.10 OWNERS MANUAL 07/05/2012

www.lightronics.com

Lightronics

Inc.

509

Central

Drive

Virginia

Beach,

Va

234354

757

486

3588

SIMPLE REMOTE CONNECTIONS









Scenes 1 - 8 (stored in the AB-0602A) may be used
by simple remotes. A BLACKOUT function may
also be accessed. A simple remote is any switch that
can provide a momentary contact closure which can
be applied to a specific pin on the AB-0602A simple
remote controls connector.

See the

CONTROL SIGNAL CONNECTIONS

diagram for specific connection details. The three

COM

(commons) pins are electrically tied together.

A SIMPLE REMOTE COMMON is routed to the
remote switch. When the switch is operated the
closure brings the common back to the applicable
pin

(SW1 - SW8)

on the simple remote controls

connector in the AB-0602A. Contact SW9 is the
BLACKOUT. Almost any available low voltage
wire may be used since these connections are just
contact closures.

Multiple simple remotes may be used. Additionally
multiple AB-0602A units may be chained to one or
more simple remotes.

An example remote of switch operation using a
Lightronics APP01 switch is shown below. It can
activate scene 1 and invoke a blackout.





















OPERATION

SETUP AND OPERATING CONFIGURATION

All operating functions and settings for the AB-
0602A are menu controlled using the LED Display
and the 4 buttons located below it on the control
circuit board.







FACTORY DEFAULT CONFIGURATION

The AB-0602A is supplied with a factory default
setup configuration. The unit may be reset to this
condition by keeping the

SELECT button held

down while power is applied. The display briefly
shows

FACt

while the reset is being performed.

The AB-0602A is set as follows when a reset is
performed:

1. The DMX pack address (

PACA

) will be set to

DMX address 1 (

P001

).

2. Softpatch is set to DMX addresses 1 - 6
3. Dropout trip points are set to 35 (14%).
4. All channels curves are set to

LED1

.

5. The architectural ID

(ArCU)

is set to

00.

DISPLAY STATUS INDICATORS

The LED display shows a dot near the upper left
corner when a valid DMX signal is being received.

MENU ACCESS AND USE

Hold the

MENU/NEXT button down for aprox. 5

seconds to gain access to the complete menu system.
If there is no button activity for 1 minute while
inside the menus then the unit will revert back to the
normal display (

PACA

).

To exit from anywhere in the menus - Hold down
MENU/NEXT for aprox. 5 seconds. The unit will
revert back to the normal display (

PACA

).

A menu/display operation flow diagram is provided
at the back of this manual.

CAUTION

REMOVE ALL POWER FROM THE AB-0602A

BEFORE MAKING OR CHANGING SIMPLE

REMOTE CONNECTIONS.

P A C A

MENU

NEXT

SELECT

DMX VALID

SIMPLE REMOTE

CONNECTION EXAMPLE

Advertising
This manual is related to the following products: