Magnum Venus Plastech UltraMAX MVP Installation & Set-Up User Manual

Mvp - ultramax™ installation & set-up

Advertising
background image









CHECKLIST


1.

Check all clamp brackets, pump column, slave arm bracket, manifold
clamp, etc. to make sure they will not move when unit is in operation.


2.

Check the mounting of catalyst pump to make sure clevis pins are
secure.


3.

Make sure exhaust silencer is secured to the power cylinder of the
resin pump.


4.

IMPORTANT: Snug up the packing nut at the top of the catalyst
pump approximately ¼ turn.


5.

Snug up, tighten, the resin pump packing by inserting two rods into
the holes in the oil cup at the top of the resin pump fluid section.
Turn clockwise until packing is snug. Note: Do not over tighten.


6.

ProGun: Tighten the gun valve rod packing nuts until they are very
snug. IMPORTANT: Activate the gun trigger 10 - 15 times then
tighten the packing nuts.
Repeat this tightening procedure 3 times
to make sure the gun valve rod packing is tight.


7.

Attach Suction Wand to Resin Pump.


a. Check all fittings on the wand assembly to make sure they are

airtight.

b. Attach the wand assembly to the foot valve port of the resin

pump.


8.

Hose connections.


a. Connect the black resin hose from the gun to the outlet fitting on
the resin filter.

b. Connect the catalyst hose from the catalyst pump to the inlet of the catalyst manifold.

c. Connect the catalyst hose from the gun to the outlet of the catalyst manifold assembly.

d. Attach the red air hose from the gun to the fitting on the regulator labeled gun.

e. Attach the yellow poly flush hose from the gun to the outlet fitting of the solvent tank.

f. Attach the small red air supply hose from the flush regulator to the input fitting on the solvent

tank.

g. Attach the large red air hose from the pump regulator to the power cylinder of the resin pump.

Note: Check all hose fittings and fluid connections to make sure they are tight.

MVP -

UltraMAX™

Installation & Set-Up

Advertising