h. Attach the ground wire from the gun to the electrical grounding lug on the pump mounting

bracket.


Note:

Check electrical ground to ensure it is installed from the pump mounting bracket to an

earth ground.

i. Remove the catalyst poly tubes from the component box.

j. Cut the ½ inch diameter poly line, with the clamps, to 26 inches long. Clamp one end to the

outlet of the catalyst jug and the other end to the inlet of the catalyst pump. Make sure clamps

are airtight.

k. Connect the ¼-inch poly line to the relief valve on the catalyst manifold assembly and insert

the other end into the hole in the top of the catalyst jug.

l. Connect the ¼-inch poly line to the catalyst recirculation valve on the catalyst manifold, and

insert the other end into the hole in the top of the catalyst jug.


9.

Check all components for damage.