Ground pole installation 2 ³⁄₈” o.d. x 72” long, Parts and hardware listing, Fig. 1.0 – Andrew TYPE 100 User Manual

Page 4

Advertising
background image

7

15

8

5

6

9

11

13

12

4

6

14

CLAMP
SURFACE

9

6

7

10

Junction Block (9)

GROUND POLE INSTALLATION

2

³⁄₈” O.D. x 72” LONG

;;

;;

;;

;;

;;

;;

72

37

d

36

1" to 2"
SLOPE FOR
WATER RUN OFF

GRADE

BELOW
FROST LINE

OVAL END

MIN.
DIA.

2

³⁄₈" O.D.

PIER
FOUNDATIONS

;;

;;

;;

;;

;;

;;

;;

;;

;;

;;

;;

;;

;;

72

37

d

48"

1" to 2"
SLOPE FOR
WATER RUN OFF

GRADE

BELOW
FROST LINE

OVAL END

MIN.
DIA.

NOTE:

48" may be

increased, concrete

and length of rebar

will increase

accordingly.

2

³⁄₈" O.D.

DEEP
FROST LINE
FOUNDATIONS

;

;

;;

;;

;;

(SEE NOTE)

1-1.5"

APPROX.

2"

;;

;;

(4) #3 x 24" MIN.

AT 90˚ APART

(SEE NOTE)

2

11

PARTS AND HARDWARE LISTING

FIG. 4.1 - ANTENNA, ANTENNA FEED (LNB) & FEED SUPPORT LEGS

ANT

WIND VEL.

DIM “d”

CONC VOL.

DIM “d”

CONC VOL.

GROUND POLE

80 MPH

9”

1.5 FT

3

7”

1.2 FT

3

90 MPH

11”

2.2 FT

3

7”

1.2 FT

3

Mo. 611652931

90cm

100 MPH

13”

3.0 FT

3

8”

1.5 FT

3

110 MPH

15”

4.0 FT

3

10”

2.4 FT

3

SEE NOTE 1

125 MPH

18”

5.8 FT

3

12”

3.5 FT

3

80 MPH

10”

1.8 FT

3

7”

1.2 FT

3

Mo. 611652931

1.0M

90 MPH

13”

3.0 FT

3

8”

1.5 FT

3

100 MPH

15”

4.0 FT

3

9”

1.9 FT

3

SEE NOTE 2

108 MPH

16”

4.6 FT

3

10”

2.4 FT

3

PIER FOUNDATIONS

DEEP FROST LINE FOUNDATIONS

POLE SPECIFICATIONS:

2” SCH 40 2

³⁄₈” O.D. x .154 Wall x 72” Long Steel - CM PN 611652931 w/Oval End and

Powder Paint Finish.

1. When wind velocity exceeds 108 MPH on the 90cm antenna at heights shown, the

ground pole must be a heavy wall pipe as follows: 2” pipe (2

³⁄₈” O.D.) Schedule 80

(.218” wall thickness) and purchased locally. Field weld

¹⁄₄ x 1¹⁄₂ x 5 key as shown in

Fig. 1.0 to prevent rotation in the concrete or use 3” O.D. ground pole and AZ/EL cap.

2. These charted values based on using Model 611652931 ground pole, 2.375 O.D. x

1.54 wall. When wind velocity exceeds 108 MPH, use 3” O.D. ground pole and AZ/EL
cap.

3. Pole and foundation design based on the following criteria: (a) Uniform Building

Code Exposure C and 1.5 stability factor, (b) Vertical soil pressure of 2000 pounds
per square foot, (c) Lateral soil pressure of 400 pounds per square foot, (d) Concrete
compressive strength of 2500 pounds per square inc h in 28 days.

4. CAUTION - The foundation design shown does not represent an appropriate design

for any specific locality since soil conditions vary and may not meet design criteria
given in Note 1. You should consult a local professional engineer to determine your
soil conditions and appropriate foundation.

;;

;;

;;

;;

;;

;;

;;

;;

6"

APPROX.

;;

;;

KEY

¹⁄₄ x 1¹⁄₂ x 5

FIELD WELD

.21

.21

FIG. 1.0

ITEM

DESCRIPTION

QTY.

4

LEG BOTTOM (90cm)

1

4

LEG-BOTTOM-FEED (1.0m)

1

4

LEG-BOTTOM-FEED (1.2m)

1

5

REFLECTOR-SMC 1.0m

1

5

REFLECTOR-SMC 1.2m

1

5

REFLECTOR-SMC 90cm

1

6

LEG-SIDE-FEED (1.0m)

2

6

LEG-SIDE-FEED (1.2m)

2

6

LEG-SIDE-FEED (90cm)

2

7

BOLT-HEX M6 x 30

4

8

WASHER, FLAT

¹⁄₄” x ⁷⁄₈”

2

9*

BLOCK-JUNCTION

1

10

WASHER-FLAT

¹⁄₄” x ³⁄₄” O.D.

2

11*

CLAMP-HALF-JCT.

1

12*

BOLT HH M6 x 20

2

13*

WASHER-FLAT M6 x

¹⁄₂” O.D.

2

14*

KU-FEED ASSY.

1

15

SCREW-TPG-SPL M6

1

*Provided in feed assembly.

Advertising