Remove mix housing – Magnum Venus Plastech High Volume Pro Gun 60625-1 User Manual

Page 21

Advertising
background image

High Volume Pro Gun Manual

Rev. 05/2012

Page | 21

Remove Mix Housing

1.

Remove the nozzle cap from the mix housing.


2.

Remove the nozzle from the cap.


3.

Remove the mix housing (58132-1) by unscrewing the screws holding the mix
housing to the gun block.

SCREW

MIX HOUSING

DISTRIBUTION RING

MIX HOUSING SEAL

INJECTOR ASSEMBLY

HV TURBULENT MIXER

HV NOZZLE ADAPTOR

NOZZLE SEAL

NOZZLE

NOZZLE CAP


4.

Pull the injector and injector seal out and set the injector assembly aside.


5.

Remove the turbulent mixer from the mix housing.


6.

Use a blunt tool to push the distribution ring™ and housing seal out of the mix
housing.


7.

Inspect and clean the mix housing components with solvent.