Remove mix housing – Magnum Venus Plastech High Volume Pro Gun 60625-1 User Manual
Page 21
Advertising
High Volume Pro Gun Manual
Rev. 05/2012
Page | 21
Remove Mix Housing
1.
Remove the nozzle cap from the mix housing.
2.
Remove the nozzle from the cap.
3.
Remove the mix housing (58132-1) by unscrewing the screws holding the mix
housing to the gun block.
SCREW
MIX HOUSING
DISTRIBUTION RING
MIX HOUSING SEAL
INJECTOR ASSEMBLY
HV TURBULENT MIXER
HV NOZZLE ADAPTOR
NOZZLE SEAL
NOZZLE
NOZZLE CAP
4.
Pull the injector and injector seal out and set the injector assembly aside.
5.
Remove the turbulent mixer from the mix housing.
6.
Use a blunt tool to push the distribution ring™ and housing seal out of the mix
housing.
7.
Inspect and clean the mix housing components with solvent.