Output Frequency Select:

S3: Rotary switch allows selection of output resolutions of 24 to 1000 pulses per revolution (square
wave output), or 12 to 500 pulses per revolution (per phase) if the 2-phase output option is selected.
The resolution can be changed while the tachometer is operating, and the new value will take effect
immediately. See chart below for resolution at each switch setting.

J2: Header for Factory Programming Only

D10: Direction/Phase B (Terminal 6

Status) (High = Green, Low = Red)

*

D11: Output/Phase A (Terminal 4/5
Status) (High = Green, Low = Red)

S4-2: Output Select (2- Phase or Combined
Output) Assigns outputs of Terminals 4-6 and
D10 and D11.

S5: Calibrate Stator Offsets

(and Angle). Need S3 in
position 0 to start Calibration.

S3: Output Frequency Select

And Calibration Enable

D7: Microcontroller Memory
Status (On = Fail)

S4-1: Select Meter Type
Type

Stator Phase A Testpoint

Stator Phase B Testpoint

Common Testpoint

S1-1: Ground

S1-2: Filter

Terminal Block
1. Case (Green)
2. Common (Black)
3. Power 5-30VDC (Red)
4. Combined Output (White)
5. Phase A Out (Orange)
6. Phase B Out or Direction (Blue)

S2: Reset Microcontroller

D8: Flow too low to calibrate

D9: Calibration Active

D3-D6: RVDT Rotor Position
Indication (4 LED’s)

S3

2-Phase

Combined

Position

Output

Output

0

0 (Calibrate)

0 (Calibrate)

1

12

24

2

25

50

3

50

100

4

100

200

5

150

300

6

250

500

7

300

600

8

500

1000

9

*

*

Cycles per Revolution

* Not Specified, Usually same as S3=8

286-300-350 © 2002, Max Machinery, Inc.

Outputs, Options & Indicators

(7)

* Phase A leads Phase B when meter
is turning CCW (forward flow on
piston and gear style meters, reverse
flow on helix meters). Indicated at
terminal 6 by a 5 VDC signal and the
changing of D10 to green.