Discontinued, User options and adjustments – Max Machinery 272-5X8 BIDIRECTIONAL TRANSMITTER (210_240 SERIES FLOW METERS) User Manual

Page 10

Advertising
background image

Table I list the approximate volumetric displacements of flow meters that can be used with the 272

transmitters. Use this table to calculate the RPM of the flowmeter at maximum flow.

TABLE 1: METER MAXIMUM FLOW AND DISPLACEMENT

FLOWMETER

MAXIMUM FLOW

DISPLACEMENT PER REVOLUTION

MODEL

CC/MIN

GAL/MIN

CC

GALLONS

213

1,800

0.48

0.870

.00023

214

10,000

2.64

10.5

.00285

215

40,000

10.6

47.6

.0128

216

100,000

26.4

169.5

.0446

220

10,000

2.64

9.12

.0024

221

55,000

14.5

23.5

.0062

222

75,000

19.8

47.4

.0125

241

189,000

50.0

62.1

.0164

251

189,000

50.0

62.1

.0164

242

540,000

143.0

182.0

.0480

243

1,400,000

370.0

574.0

.152

244

3,500,000

925.0

1700.0

.456

245

8,000,000

2114.0

6060.0

1.60

FOR EXAMPLE: THE MODEL 213 MAXIMUM RPM IS: 1800 CC/MIN ÷ 0.870 CC/REV = 2069 RPM.

Table II list the RPM range of each Range Switch setting for all three 272 transmitters. Use this

table to estimate the correct range position.

TABLE 2: RPM RANGE VS SWITCH POSITION

(RPM AT 10V OUT)

272-5X5

272-5X7

272-5X8

SWITCH

MAX

MIN

MAX

MIN

MAX

MIN

POSITION

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

1

1985

5559

2197

6157

1985

5559

2

794

2224

879

2460

794

2224

3

318

889

351

984

318

889

4

127

356

141

394

127

356

5

51

142

36.3

117

51

142

6

20.3

57

21

53

20.3

57

Page 10

272-500-350 © 1996 (Rev. 8/00) Max Machinery, Inc.

USER OPTIONS AND ADJUSTMENTS

Discontinued

Advertising