Communicate via snmp/web/ network adapter, Access ups functions via the web and also, Optional maintenance bypass – MaxPower Corp UniStar C Rack_Tower User Manual

Page 4

Advertising
background image

www.stacoenergy.com

Emergency shutdown control

through EPO allows users to shut

down the UPS completely in an

emergency to ensure a safe operating

environment.

Communication software allows

not only the control of the UPS and its

smooth shutdown when Utility fails,

but also allows the user to

Completely test the major operating

functions of the UPS

Communicate via SNMP/Web/

Network adapter

Access UPS functions via the Web

and also

Alert users via SMS messages

against specifi c events

Custom options slot allows further

fl exibility in network confi guration.

An internal WEB/SNMP card, AS/400

card, USB card and True Relay card

provide isolated contacts for industrial

and remote alarm panel application.

User-friendly Plug-and-Play design

allows hassle-free installation. All units

up to 3kVA are supplied with input

cables and output receptacles as

standard.

Innovative battery management

circuit analyzes battery discharging

status to adjust battery cut-off point

and extend the batteries’ life span.

Internal maintenance-free sealed-

type battery minimizes the need for

frequent after-sales service. The hot

swappable battery feature can enable

users to replace the batteries without

the hazard of electric shock, while

the UPS supplies power continuously

to critical load applications.

Built-in Charger provides ability

to re-charge internal battery to

approximately 90% in four hours.

Matching battery cabinets are available

to extend the UPS runtime easily to

several hours.

Optional extended runtime

capability by simply connecting

additional battery packs. Just plug in

the battery connectors between the

UPS and battery packs without the

requirement for additional chargers.

Extended run time battery packs

are available for all models. Size,

capacity and estimated run times

are shown in the table below. Back

up time is for the battery pack used

with the UPS internal batteries.

Battery packs are external and hot

swappable.

Optional Make-Before-Break

Bypass Switch—manually operated,

external—ensures continuous supply

of power to the critical load in the

event of unexpected or scheduled

maintenance.

Battery Run Time Chart (shown in minutes)

UPS
Size

Part
Number

Quantity

25%

Load

50%

Load

75%

Load

100%

Load

H x W x D (inches)

Weight

(lbs. each)

I kVA

Internal

0

50

20

10

7

N/A

N/A

USC-BP1K

1

380

160

95

66

3.5" x 17.3" x 25.6"

83

2

740

320

195

130

3.5" x 17.3" x 25.6"

83

3

1150

505

310

215

3.5" x 17.3" x 25.6"

83

4

1575

695

430

300

3.5" x 17.3" x 25.6"

83

2kVA

Internal

0

45

18

10

7

N/A

N/A

USC-BP3K

1

195

80

45

33

3.5" x 17.3" x 25.6"

87

2

320

155

95

66

3.5" x 17.3" x 25.6"

87

3

550

240

145

100

3.5" x 17.3" x 25.6"

87

4

745

325

195

135

3.5" x 17.3" x 25.6"

87

3kVA

Internal

0

40

15

8

5

N/A

N/A

USC-BP3K

1

163

65

40

25

3.5" x 17.3" x 25.6"

87

2

305

130

75

53

3.5" x 17.3" x 25.6"

87

3

460

195

120

80

3.5" x 17.3" x 25.6"

87

4

650

280

170

120

3.5" x 17.3" x 25.6"

87

Notes: Battery rated at 12V; 1/2kVA 7A/hour, 3kVA 9A/hour, 1kVA 36V, 2/3kVA, 72V

Optional Maintenance Bypass

Model Number

Rating/Voltage

Input Connection

Output Receptacles

USC-MBPDU-11RT

1kVA / 120V

Attached 6' Cord with 5-15P

(8) 5-15R

USC-MBPDU-21RT

2kVA / 120V

Attached 6' Cord with 5-20P

(6) 5-15R & (2) 5-20R

USC-MBPDU-31RT

3kVA / 120V

Attached 6' Cord with L5-30P

(4) 5-15R & (1) 5-30R

USC-MBPDU-12RT

1kVA & 2kVA / 230V

Attached 6' Cord with IEC C14

(8) IEC C13

USC-MBPDU-32RT

3kVA / 230V

Attached 6' Cord with IEC C20

(6) IEC C13 & (1) IEC C18

Dimensions: 3.5" H (2U) x 17.3"W x 3.0"D