C rack/tower universal design, Unistar, 1kva, 2kva & 3kva – MaxPower Corp UniStar C Rack_Tower User Manual

Page 5

Advertising
background image

Model

USCH-10001

USCH-20001

USCH-30001

USCH-10002

USCH-20002

USCH-30002

INPUT
Voltage Range

60Vac – 144Vac Software Selectable

120Vac – 288Vac Software Selectable

Frequency

50/60 Hz Auto-Select, +/- 5Hz

Phase/Wire

Line + Ground

Power Factor

>0.99 at Rated Full Linear Load

Transfer Time

0 ms

AC Leakage Current

5mA

<3.5mA

Surge Protection

400 joules

300 joules

OUTPUT
Capacity

1kVA/800 Watts

2kVA/1600 Watts

3kVA/2400 Watts

1kVA/800 Watts

2kVA/1600 Watts

3kVA/2400 Watts

Voltage

100/110/115/120/127Vac Software Selectable

200/208/220/230/240Vac Software Selectable

Voltage Regulation

+/- 1%

Frequency
(Sync Range)

3Hz or 1Hz Software Selectable

Frequency
Battery Mode

+/- 0.1% (0.05 ~0.06Hz)

Crest Factor

3:1

Harmonic Distortion

< 3% THD (Linear Loads), < 7% THD (Non-Linear Loads)

Transient Response

< = 60ms/5%

Waveform

Pure Sine Wave

Effi ciency AC Mode

85%

85%

88%

85%

85%

88%

Effi ciency Bat. Mode

83%

83%

85%

83%

83%

85%

DC Start

Yes

Cooling

Load Dependent Variable Speed Fans

Over temperature

Normal Mode -Transfer to bypass; Battery Mode – UPS shuts down immediately

Overload

<105% continuous, >120% for 30 seconds, >150% for 10 seconds

DISPLAY, ALARMS, DIAGNOSTICS, COMMUNICATIONS & EMERGENCY FUNCTION

Status On LCD

Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnected, Overload,

Transferring with interruption & UPS Fault

Readings On LCD

Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Units Inner Temperature

Power Up

ON/OFF Button, Test Alarm & Reset Button

Self-Diagnostics

Upon Power –On, Front Panel Setting & Software Control, 24 Hour self check

Audible Alarms and Visual

Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions

Communications

RS232 Serial Port and USB, optional SNMP/WEB, USB or Dry Contact Cards

Emergency Power Off
(EPO) Connection

Emergency Power Off shuts down UPS when activated by customer supplied EPO Circuit

CONNECTIONS

Input

6' Cord w/ 5-15P

6' Cord w/ 5-20P

6' Cord w/ L5-30P

6' Cord with 10A,

IEC 320-C14

6' Cord with 10A,

IEC 320-C146’

6' Cord with 16A,

IEC 320-C20

Output

(6) 5-15R

(2) 5-15R &

(2) 5-20R

(4) 5-15R &

(1) L5-30R

(6) 10A,

IEC 320-C13

(6) 10A,

IEC 320-C13

(4) 10A,IEC 320-C13

& (1) 16A,

IEC 320-C19

Output Control

(2) ON/OFF Software controlled receptacle banks for load shedding

PHYSICAL

Dimensions
H" x W" x D"

Rack Confi guration 1kVA 3.5 x 17.3 x 16 2/3kVA 3.5 x 17.3 x 25.6
Tower Confi guration 1kVA 17.3 x 3.5 x 16 2/3kVA 17.3 x 3.5 x 25.6

Weight (lbs.)

34.5

64.7

65.3

34.5

64.7

65.3

Safety and Performance

UL1778, c-UL, CE, IEC/EN 62040-1-1, IEC 60950-1, IEC/EN 62040-2 Class A, IEC/EN55011, CISPR11, IEC61000-4-2/-3/-4/-5,

IEC61000-2-2, IEC61000-3-2/-3,FCC Part 15 Subpart B Class A

ENVIRONMENTAL
Operating Temp.

0° C – 40° C

Noise Level

<50dBA @ 1 Meter

Relative Humidity

0 to 90% non-condensing

INTERNAL BATTERY
Battery Run Time
@ Full Load

7 Minutes

5 Minutes

7 Minutes

5 Minutes

Type

3 each, 12V/7AH

Sealed Lead Acid

Maintenance Free

6 each, 12V/7AH

Sealed Lead Acid

Maintenance Free

6 each, 12V/9AH

Sealed Lead Acid

Maintenance Free

3 each, 12V/7AH

Sealed Lead Acid

Maintenance Free

6 each, 12V/7AH

Sealed Lead Acid

Maintenance Free

6 each, 12V/9AH

Sealed Lead Acid

Maintenance Free

Charging Current

1.1Amps

2.16Amps

2.7Amps

1.1 Amps

2.16 Amps

2.7 Amps

Charging Voltage

41.0Vdc +/-0.5V

82.0Vdc +/-0.5V

82.0Vdc +/-0.5V

41.0Vdc +/-0.5V

82.0Vdc +/-0.5V

82.0Vdc +/-0.5V

Hot – Swappable

Yes

Recharge Time

4 hours to 90%

Extended Battery

Yes – Hot Swappable (Refer To Run Time Chart)

UniStar

®

C

1kVA, 2kVA & 3kVA

UniStar

®

C Rack/Tower Universal Design