Table.1 – MaxPower Corp GE VH Series User Manual

Page 5

Advertising
background image

Modifications reserved

Page 5/5

TDS_VHE_XXX_0K7_2K0_XGB.doc

Technical Data Sheets VH700-2000VA UL

Table.1

Dimensions and battery run times

UPS block di agram, protections and cable sections






















Recommended external fusing of input wiring

Cable sections input and output recommended

by NEC standards

Alternatively, local standards to be respected

UPS

Model

Mains / Bypass input

CABLE SECTIONS

mm

2

AWG

VH 700

15A Class “B“ MCB

1.8

16

VH 1000

15A Class “B“ MCB

1.8

16

VH 1500

20A Class “B“ MCB

2.5

14

VH 2000

20A Class “B“ MCB

2.5

14

UPS

Model

Backup

time

(min.)

Total

capacity

(Ah)

Nr. of

extra

battery

cabinets

Battery cabinet

UPS cabinet

Dimensions

( HxWxD )

Weight

Shipping

weight

Dimensions

( HxWxD )

Weight

Shipping

weight

VH700

8

7

---

---


3.4x17.2x18.5 inch

87x438x470 mm

35 lbs/16 kg

49 lbs/22kg

VH1000

8

9

---

3.4x17.2x18.5 inch

87x438x470 mm

60 lbs

27kg


68 lbs

31kg

37 lbs/17kg

53 lbs/23kg

26

23

1

48

37

2

66

51

3

VH1500

7

7

---

3.4x17.2x21.3 inch

87x438x540 mm

101 lbs

46kg

110 lbs

50kg

3.4x17.2x21.3 inch

87x438x540 mm

64 lbs/29kg

73 lbs/33kg

35

21

1

63

35

2

88

49

3

VH2000

8

9

---

71 lbs/32kg

79 lbs/36kg

26

23

1

50

37

2

74

51

3

APPLIANCE OUTLETS

OFF

ON

BATTERY

CHARGER

OPTIONAL

MICRO-PROCESSOR CONTROL

BATTERY

EXTENSION

BATTERY

BOOSTER

BATTERY

INPUT

CONVERTER

OUTPUT

CONVERTER

RFI

FILTER

BYPASS

AUTOMATIC

BYPASS

RFI

FILTER

INPUT:
MAINS POWER WITH DISTURBANCES

FROM

MAINS

OUTPUT:
PERFECT UPS POWER

USB

RJ11

USB

RS232

Relay

(optional)

FRONT PANEL

Advertising