Firstline, Flexibility, Main characteristics – MaxPower Corp FirstLine PL User Manual

Page 2: Battery care system

Advertising
background image

FirstLine

®

P

L

UPS

Mimic Panel

Flexibility

FirstLine

®

PL models feature an output

transformer with galvanic isolation
(between the load and the battery
supply) to provide greater versatility
and installation options. The UPS can
be supplied from two separate power
sources (main power and a second
emergency standby source) which
helps increase the resilience of parallel
system configurations.

In the event of an AC power
failure, the FirstLine® PL UPS will
automatically transfer to battery
power and continue to provide
power without any interruption
for the full amount of time you
select. When power returns,
the FirstLine

®

PL UPS will

automatically recharge the
batteries for the next unexpected
power outage or disturbance.

AC Input Performance

FirstLine

®

PL is a further evolution of

the FirstLine

®

series with the added

advantages offered by an IGBT-based
rectifier/inverter assembly. This feature
reduces the impact of the UPS on the
local supply and simplifies installation
where there is limited power capacity
in the form of available electrical supply
rating or generator size. FirstLine

®

PL is

classed as a “Zero Impact Source” and
provides:

n

Low input current distortion—

<1 % (THDi) @ full load

n

High input power factor 0.99

n

Power walk-in function that ensures
progressive rectifier start up

n

Delayed start up phased with the
return of mains power supply, when
several UPS are connected in the
system.

FirstLine

®

PL also performs the role of a

high performance filter, protecting its
upstream power supply sources from
any harmonics and reactive power
generated by the loads powered.

www.stacoenergy.com

FirstLine

®

P

L

Main Characteristics

n

Efficiency up to 94%

n

Reduced weight

n

Double electronic and

galvanic protection of
the load from the battery

The entire FirstLine

®

PL

range is suitable for a
wide range of applications
thanks to the flexibility of
configurations, accessories,
options, and choice of
performance levels. The
UPS is compatible with
capacitive loads, such as
blade servers, without
any reduction in active
power, ranging from 0.9
lead to 0.8 lag and up to
0.8 capacitive power with a

low derating equal to 15% of the active
power (kW). Efficient and reliable power
supply for mission critical applications is
guaranteed by operating in redundancy
and power parallel mode with up to
4 units (N+1), and by the Dual Bus
System and Dynamic Dual Bus system
configurations.

Battery Care System

FirstLine

®

PL uses the Battery Care System

which optimizes battery performance
while extending battery life.

1

a

b

c

d

e

3

2

1

(LCD) Graphic LCD

ENT Key

<

ENTER

>

ESC Key

<

ESC

>

( ) Key move up

2

( ) Key move down

( ) Key move to right

( ) Key move to left
(a) Rectifier Input Voltage OK led (green)

(b) Output Volltage Unit from the Bypass led (orange)

3

(c) Inverter is Working led (green)

(d) Unit Working from Batteries--mains failure led (red)

(e) General Alarm--in case of any alarm of the unit led (green)

Advertising