Two Year Warranty

Electronics:

A full Two Year On-site Warranty (Continental U.S.)

Battery:

A full One Year Warranty, 10-year pro-rated,
on the Battery System ensures that your batteries
are protected from system failure now and in the
future. (Warranty provided by battery manufacturer.)
Extended warranties, customized service plans and
preventative maintenance are also available. Please
refer to our warranty statement for complete details.

Staco Energy Products Co.

Staco FirstLine PL UPS Technical Specifications

UPS Rating kVA/kW

10/9

15/13.5

20/18

30/27

40/36

Input

Topology

On-Line Double Conversion

Voltage

208Y/120 VAC, Three Phase, 4 wire plus ground or 220Y/127 VAC configurable from the Front Panel

Range

+15% / -20% Battery Discharge@-15% with full load

Frequency

60/50Hz +/- 5.0 Hz

Power Factor

0.99 at 100% load, 0.98 minimum at 50% load

Current Distortion (THD)

<1% @100% Load, <2% @ 50% Load, <5% @ 10% Load

Input Current (A)

Nominal: 28

Maximum: 33

Nominal: 42

Maximum: 49

Nominal: 55

Maximum: 65

Nominal: 83

Maximum: 97

Nominal: 111

Maximum: 130

Input Current Inrush

Walk-In from 25% maximum to 100% full load rating in 5 seconds

Output

Voltage

208Y/120 VAC, Three Phase, 4 wire plus ground or 220Y/127 VAC configurable from the Front Panel

Static Voltage Regulation

+/- 2%

Voltage Transient Response

Voltage transient response shall not exceed the following, and shall recover to 95% within 10 milliseconds:

a) +/- 15% at the first cycle for a 100% step load b) +/- 1% (loss or return of AC input)

Frequency

(inverter synchronous)

60/50Hz (tracks frequency of static bypass source) +/- 0.5, 1.0, 2.0, 5.0 Hz (user settable)

Frequency Slew Rate (inverter

synchronized to static bypass)

± 10 Hz per second

Free Running Frequency

(on battery or asynchronous)

60/50Hz +/- 0.01Hz

Voltage Distortion THD

Less than 1% (Linear load), less than 2% with crest factor 2.5 to 1

Inverter Overload

125% for 10 minutes, 150% for 60 seconds

Bypass Overload

400% for 10 seconds, 1000% for half line cycle

Bypass Input – Range

Synchronization Voltage

+12% / -15%

Bypass Input Frequency

Tracking Range

+/- 5Hz

Overall Efficiency

Up to 94%

Output Current (A)

28

42

55

83

111

Heat Rejection (BTU/Hr)

3,412

5,118

6,824

10,237

13,649

Battery Run Time (minutes)

Internal Battery String

Model (-X)

(-1) 37, (-2) 18, (-3) 9 (-1) 21, (-2) 10, (-3) 4

(-

1) 14, (-2) 6

(-1) 8

(-1) 4

Environmental

Altitude

De-rate load capability above 1000 meters, 1% per 100 meters

Operating Temperature

40 °C Maximum

Audible Noise

@ 3 feet "A" weighted scale

61dBA

67dBA

Dimensions and Weights

H x W x D inches (mm)

41.7 (1059) x 20.3 (516) x 33 (838)

52 (1321) x 23.2 (589) x 33 (838)

- (X) model, Lbs. (kg)

-0, 410 (186) -1, 950 (431)

-2, 735 (334) -3, 630 (286)

-0, 585 (266)

-1, 1,125 (510)

-0, 585 (266)

-1, 1,185 (538)

Standard Communications

SNMP/WEB

SNMP Card & UPS PowerView Pro Shutdown and Monitoring Software for Windows/Novell

Modbus

Monitoring & Control via RS-485/RTU Protocol/Read Holding and Write Registersl

Options

Input/Output

480/480V (D or Y), 480V/208V (D or Y) with Transformer option

Standards

208V Model

UL listed to 1778, CUL to CSA C22.2, NEMA PE-1, ASME, ASA-C-39.1-1984, FCC Part 15 Subpart J Class B,

NEC, OSHA, IEEE587, ANSI C 62.41-1980, ISO9000

FirstLine PL 10-40kVA Models

PL Model

kVA/kW

Internal Battery Time (minutes)

FLP-010-0

10kVA/9kW

0

FLP-010-1

37

FLP-010-2

18

FLP-010-3

9

FLP-015-0

15kVA/13.5kW

0

FLP-015-1

21

FLP-015-2

10

FLP-015-3

3

FLP-020-0

20kVA/18kW

0

FLP-020-1

14

FLP-020-2

6

FLP-030-0

30kVA/27kW

0

FLP-030-1

8

FLP-040-0

40kVA/36kW

0

FLP-040-1

4

Note: Longer battery run time available

For Frequency Converter add -FC to PL Model Number.