OPerATION AND DIAGNOsTICs

DnD-Portal™ user profile

• Unassisted, automatic drive/walk-through measurement for

DnD-Portal™ user triggered by light barriers

DnD-Portal™ operator profile

• Status of walk/drive-through measurement indicated by lights

on the monitor

• Detailed measurement and speed-test results on work station

screen

• In-depth analysis results available instantaneous on work

station

DnD-Portal™ automatic measurement routines

• Background updated every second (while monitor is

unoccupied) for each detector for automatic background
subtraction (100 ms for vehicle version)

• Background count rate monitoring with

min. and max. alarm

thresholds

• Measurement algorithm uses two median filters to follow any

background change in real time (one for vehicle version)

• Monitor is permanently ready to measure

DnD-Portal™ measurement process

• Detect person/car/truck via light barrier on entrance and exit

for measurement start/end definition

• Calculate alarm level from count rates from detector
• Return to “ready for measurement” on clean results
• Alarm operator and display graphics to identify the

radioactive source on the body/car/truck

• Prepare individual results for all detectors available for

operator via detail button on screen

• Store measurement results in database (export to an ASCII/

CSV file enabled)

• Full intranet access to database with explorer browser using

CeMoSys™ (Central Monitoring System) (option).

Detector efficiency report menu

Detector location display

Alarm level and detection safety calculation in measurement electronic

Examples of displays at the operator workstation cubicle

for vehicle (left) and personnel configuration (right)

Maintenance

• All functions available via graphic interface
• Set-up of all parameters and maintenance tools
• Detailed information on the status of all detectors
• Plug and play accessibility for the whole monitor to ease

maintenance

• Check of all binary inputs and outputs
• Database with export to USB device or compact disc
• Check function for all detectors, interfaces and

connections to quickly identify faults

• Test of each detector with the optional detector alarm

test to guarantee an optimized secure performance

“system Check” calibration tool

• Single and multiple source calibration of any channel
• Database for calibration sources, automatic calculation

of current activity

• Reference calibrations automatically transferred to

measurement software

• Comparison of detector efficiencies with reference

database for storage of calibration results

• Results can be printed and exported to USB device

Two Step - quick fittings

High alarm value

High alarm level

Alarm value

Alarmlevel

low alarm value

Median backgr

ound

Detectionsafety

Detectionsafety

Falsealarmsafety

t

Cps

Response to radiological threats should be swift, scalable and powerful -

that’s why we came up with the RADOS DnD-Portal™.

Advertising