50 Ton Ram Instruction Manual
1¼" through 4" Standard & Long Holedall Swaged Couplings
customer service
800
•
355
•
1991
2
Section 2
Lubricate the outside of the ferrule with Crisco®
(recommended) or high viscosity oil or heavy duty
grease.
Assuring that the hose end is cut square, chamfer
the I.D. of the hose 1/8" at a 45° angle. This will aid
in stem insertion. If the hose is to be static
grounded, follow hose manufacturers procedure for
proper static grounding.
Lubricate the I.D. of the hose and the O.D. of the
stem with Dixon Coupling Lubricant or equivalent.
Insert the stem all the way into the hose until the ring
on the stem comes in contact with the end of the
hose.
6
5
7a
4
Slide the ferrule over the stem and over the O.D. of
the hose until the turned over portion of the ferrule