DoorKing 1812 Classic User Manual

Page 19

Advertising
background image

1812-065-U-12-13

17

MASTER

CODE

ON

Homeowner’s Phone

LAN/Cordless

1.9 Wire One 1812 - Intercom Mode

LOW VOLTAGE LINE

OUT

OUT

1878-010

IN

IN

GND

GND

INPUT

OUTPUT

Phone

Jack

Cat5e

Ground 12 AWG Min.

Not

Used

Homeowner’s Phone

LAN/Cordless

Be sure to properly ground the 1812. See
page 13 for acceptable grounding sources.

Be sure to properly ground the
surge suppressor. See page 13 for
acceptable grounding sources.

Low Voltage Surge Suppressor

DoorKing Surge Suppressor P/N 1878-010 (or
equivalent) is optional but highly recommended.
For best protection, surge suppressor ground wire
MUST be 3-ft. or less in length. Use minimum 12 AWG
wire. Refer to instruction sheet included with surge
board for complete information.

Connect to Homeowner’s Telephone

When connecting directly to a single telephone or an
un-used C.O. port on a PBX or KSU system, use the
PHONE OUT terminals only in the 1812. It must be
programmed for INTERCOM mode using this
configuration.
When the 1812 is programmed for intercom mode, it
provides the constant source of DC voltage necessary
for communication. The intercom mode also
disconnects the “PHONE IN” terminals (1 and 2)
since they are not used.
Be sure that the 1812 is programmed in the intercom
mode.

TIP

RING

The 1812 Classic operates ONLY on 24 VAC.
Use the supplied power transformer, 24 VAC,
20 VA (or UL listed equivalent) to power the
telephone entry system. DO NOT power any
other devices (electric strikes, magnetic
locks, additional 1812s etc.) from the 1812’s
power transformer. See page 13 for wire
size and run distances.

Supplied Transformer

Polarity does not matter.

TIP (+):

White/blue mark

RING (-):

Blue/white mark

Telephone Line

For complete information,
see page 12.

Phone Out

Intercom Mode

Cordless Phone Base Station

Cordless

Option

RJ-11
Phone
Connector

Remote phones throughout house.

Older Lines
Green Wire (+)

Older Lines
Red Wire (-)

Single 1812 Wiring Configuration

Use minimum 18
AWG wire for runs
up to 100 feet.
16 AWG wire for
runs up to 200 feet.
(Term. 11 and 13)

“Normally Open”

Vehicular

Gate Operator

Access Control Devices

Maglock

Electric
Strike

WA

RNI

NG

MO

VING

GA

TE

CA

N

CA

US

E

Ope

rat

e g

ate

on

ly w

hen

ga

te ar

ea i

s in

sight

and

free

of pe

opl

e a

nd obs

tru

ctio

ns

.

Do

no

t al

low

chi

ldre

n to

pl

ay

in g

ate

ar

ea

or o

per

ate

ga

te.

Do

no

t s

tan

d in

ga

te pa

th or

w

alk t

hrou

gh

path

wh

ile g

ate

is

m

oving.

Rea

d o

wne

r’s m

anua

l and

sa

fety

ins

truc

tion

s.

SERIOUS

IN

JURY

OR

DE

ATH

CLA

SS

CER

TIF

IED

TO

CA

N/C

SA

C2

2.2

NO

. 2

47

CO

NF

OR

MS

TO

AN

SI/U

L-3

25

VEH

ICUL

AR

GA

TE

OPE

RA

TO

R

HP

533

82

MOD

EL

SER

IAL

VOL

TS

PH

AS

E

AM

PS

60 H

z

MA

X G

ATE

LO

AD

Doo

rKin

g, In

c., I

ngle

wo

od,

CA

Magnetic locks or electric strikes must be
powered from a separate UL Listed power
transformer. DO NOT power strikes or
magnetic locks from the 1812 power
transformer. Use minimum 18 AWG wire for
runs up to 100 feet; 16 AWG wire for runs
up to 200 feet. It is recommended to keep
power wire runs as short as possible.

Separate UL
Listed Power
Transformer

Pedestrian

Gate/Door

“Normally Close” with Maglock

(Terminal 15 and 16)

“Normally Open” with Electric Strike

(Terminal 14 and 16)

Recommended

Recommended

77

88

99

44

55

66

00

Push Button

Push Button

To Call

To Call

Main

Terminal

1871-010

E

Note: Each relay can control a
normally open OR normally close
access control device. Relay
contacts are rated for 3 amps @
30 VAC maximum.

Phone In

(1-2)

MAST

MAST

COD

Relay 1

(11-13)

Relay 2

(14-16)

Power

(17-18)

Phone Out

(4-5)

18

17

16

Com

15

N.C.

14

N.O.

13

Com

12

N.C.

11

N.O.

10

9

8

7

6

5

RING

4

TIP

3

GND

2

1

24
VAC

Output

24

VA

C

20 V

A

DO NOT wire the
wireless adapter to the
PHONE OUT main
terminal connection.
Please refer to the
“Wireless Adapter”
manual 1815-560 for
correct wiring.

Wireless Adapter

Advertising