Installation, System components – Nitek TS510M User Manual

Page 2

Advertising
background image

Unm arked Positions are O ff

Video

Level Gain

Video

Peaking

Distance

Switch Position

1

2

3

4

5

6

7

8

<100-400 ft.

(30-121 m)

400-700 ft.

(121-213 m )

ON

700-900 ft.

(213-274 m )

ON

ON

ON

900-1,100 ft.

(274-335 m )

ON

ON

ON

1,100-1,300 ft.

(335-396 m )

ON

ON

ON

ON

>1,300 ft.

(396 m)

ON

ON

ON

ON

ON

1)

Check the twisted pair connections for continuity. This is best

done by shorting the pair of wires at one end and use an ohm meter
to check the resistance at the other end. The chart below will give
you the length of your wires for a measured resistance. Use a
multimeter to make sure there is no voltage on the line.

The TS510M is designed to power a low wattage stationary camera.
The unit is designed to work with standard 4 pair network cable. It
will provide power from the receiver unit to the camera end. The
chart below shows the maxium recommeneded operation distance
for cameras on 24AWG wire. For distances greater then the chart
a camera may be powered from a sperate supply of its own. The
TS510 M is not recommended for distances greater then 1,500 feet.

Installation

WIRE

GAGE

DISTANCE IN FEET

(METERS)

500 (152)

1,000 (304)

22

16

32

24

26

51

26

41

82

Reduce risk of fire or electrical shock do not
expose this product to rain or moisture.

Sample

Switches 1 and 2 are in “OFF” position
Switches 3 and 4 are in “ON” position

System Components

1 TR510M Active Receiver Unit
1 VB43ATF Transceiver Unit

2) At the camera, connect video to the VB43ATF via attached
BNC connector.

3)

Connect power from the VB34ATF screwless terminals to the

camera using the enclosed twisted pair wired.

4)

Plug in Category 3 or better cabling connecting VB43ATF to the

TR510M

5)

Using a power supply connect power to the screw terminals of the

TR510M active receive. The unit can be powered using 12 to 24 volts
of AC or DC current. There is no polarity to the power connection.

6)

Connect video from the TR510M to the monitor or DVR using a coax

jump cable.

7)

DIP switches are provided so that the unit can be adjusted for

best picture. The following settings are factory recommended for
normal conditions. For added sharpness adjust switches 7 and 8.
For more gain adjust 5 and 6. Switches 1, 2 and 3, 4 must be
operated in pairs.

0

200

400

600

800

1000

1200

4

4.5

5

5.5

6

6.5

7

7.5

8

Operating Distance Chart

Camera wattage

Dis

tyanc

e i

n F

eet

Advertising