Troubleshooting

Video inverted or rolling and unstable.
• Reverse the wires of the twisted pair at either
the transmitter or receiver.

No video out at the receiver.
• Check to make sure that there is video in at
the transmitter.
• Make sure that the pair of wires you are using
is not open or shorted between the transmit
and receive points.
• Check power to the receiver. The receiver must
be powered with the supplied wall pack.

Ghost image at the receiver
• Bridge tap or "T" tap on the twisted pair video
line. Remove tap.

Power Requirements

Power In - Screw Terminals
24-28 VAC 300mA 50/60 Hz
Class 2 SELV

Power Out - RJ45
24-28 VAC 250mA 50/60 Hz

TR510M

VB43ATF