aUto SHUt-off featURe

To preserve battery life, the unit may be set to

turn off automatically if no button is pressed for 20

minutes. No measurements are taken while the

unit is turned off; therefore, if alarms have been

set, they will not sound while the unit is off.
To enable the auto shut-off feature, press and hold

the CLEAR button until “AUTO OFF” appears on

the display. The unit will now turn off if no buttons

are pressed for 20 minutes. To turn the unit on,

press any button.
To disable the auto shut-off feature, press and hold

the CLEAR button until “AUTO OFF” no longer

appears on the display.

BencH StanD

The unit may be placed on a horizontal surface

by using the supplied plastic bench stand. Insert

the pegs of the bench stand into the holes located

on either side of the battery cover. The holes and

pegs are different sizes so that the stand may only

be inserted one way. Do not install the stand incor-

rectly and force it.

WaLL MoUntinG

Set a screw into the wall at the desired location.

Do not set the screw flush to the wall, the head of

the screw will need to slip into the receptacle on

the back of the unit. Once the screw has been

properly set, remove the bench stand (if installed),

and hang the unit in place by sliding the receptacle

on the back of the unit over the head of the screw.

aLL opeRationaL DifficULtieS

If this unit does not function properly for any

reason, replace the batteries with new high-quality

batteries (see “Battery Replacement” section). Low

battery power can occasionally cause any number

of “apparent” operational difficulties. Replacing the

batteries with new fresh batteries will solve most

difficulties.

BatteRY RepLaceMent

Erratic readings, a faint display, or no display are

all indications that the batteries must be replaced.

Remove the bench stand (if installed). Slide the

battery cover down in the direction of the arrow.

Remove the exhausted batteries and replace with

two new AAA alkaline batteries. Make certain to

insert the new batteries with the proper polarity as

indicated in the illustration in the battery compart-

ment. Replace the battery cover.

WaRRantY oR SeRVice