Pach and Company AeGIS 4000RTP Manual User Manual

Page 19

Advertising
background image

Pach and Company

Page 11

AeGIS 400RTP

Chapter 3. Programming

52

RELAY 2

(DOOR 2) OPEN

INTERVAL

(01-90 seconds)

60-62

DELETE

INDIVIDUAL

ACCESS CODE

60

:INDEX

NUMBER 01-20

61

: INDEX

NUMBER 21-40

62

: INDEX

NUMBER 41-50

65

DELETE ALL

ACCESS CODES

INDEX 01-50

Step 1

Entering The Programming

Mode: Press 0 and # simultaneously
then release.
If you are in the
programming mode, proceed to step 2.

Step 2

Enter the 4-digit Master

Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see Reset
Master Code.

Step 3

Enter 52 then #, you will

hear “One Short Beep”.

Step 4

Enter door 1 open interval

value (01 – 90 seconds) then press #,
you will hear “One Short Beep”.

Step 5

Enter another Function Code

to program another parameter
hear “Three Short Beeps”.

Step 1

Entering The Programming

Mode: Press 0 and # simultaneously
then release.
If you are in the pro-
gramming mode, proceed to step 2.

Step 2

Enter the 4-digit Master

Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see Reset
Master Code.

Step 3

Enter 60, 61, 62, then #,

you will hear “One Short Beep”.

Step 4

Enter another Function Code

to program another parameter; other-
wise press

∗ to exit and you will hear

“Three Short Beeps”.

Step 1

Entering The Programming

Mode: Press 0 and # simultaneously
then release.
If you are in the
programming mode, proceed to step 2.

Pick up the phone and wait for a dial
tone.

Step 2

Press # # and you will hear

“One Short Beep”.

Step 3

Press # and you will hear

“One Short Beep”.

Step 4

Enter the Function Code 52

then press #, you will hear “One Short
Beep”.

Step 5

Enter door open interval

(01 – 90 seconds) then press #, you
will hear “One Short Beep”.

Step 6

Enter another function code

to program a different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three
Short Beeps”.

Step 1

Pick up the phone and wait

for dial tone.

Step 2

Press # # and you will hear

“One Short Beep”.

Step 3

Press # and you will hear

“One Short Beep”.

Step 4

Enter 60, 61or 62, then

press #, you will hear “One Short
Beep”.

Step 5

Return to step 4 to delete

another group of access codes or
enter another function code to program
different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three Short Beeps”.

Step 1

Pick up the phone and wait

for dial tone.

Step 2

Press # # and you will hear

“One Short Beep”.

Step 1

Call to the AeGIS 400RTP

system (you must know the system’s
phone number), you will hear: “One
Short Beep”,
the gate is locked. “Two
Short Beeps”,
the gate is unlocked.

Step 2

Press # then enter a valid

master code and you will hear:
“One Short Beep”, the master code

is accepted then press # and you will
hear “One Short Beep”.

“One Long Beep”, the master code

is rejected and the connection will be
disconnected.

Step 3

Enter the Function Code 52

then press #, you will hear “One Short
Beep”.

Step 4

Enter door open interval

(01 – 90 seconds) then press #, you
will hear “One Short Beep”.

Step 5

Enter another function

code

to program a different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three Short Beeps”.

Step 1

Call to the AeGIS 400RTP

system (you must know the system’s
phone number), you will hear:“One
Short Beep”,
the gate is locked.“Two
Short Beeps”,
the gate is unlocked.

Step 2

Press # then enter a valid

master code and you will hear:
“One Short Beep”, the master code

is accepted then press # and you will
hear “One Short Beep”.

“One Long Beep”, the master code

is rejected and the connection will be
disconnected.

Step 3

Press # to enter into the

programming mode and you will hear
“One Short Beep” or

∗∗ to hang-up

the call.

Step 4

Enter 60 or 61, or 62 then

press #, you will hear “One Short
Beep”.

Step 5

Return to step 4 to delete

another group of access codes or
enter another function code to program
different parameter or exit the program
by pressing

∗ ∗ and you will hear

“Three Short Beeps”.

Step 1

Call to the AeGIS 400RTP

system (you must know the sys

tem’s

phone number), you will hear:

“One Short Beep”,

the gate is

locked.

“Two Short Beeps”, the gate

is unlocked.

Function

Local Programming

Premise Phone

Remote Phone

Advertising