Pach and Company AeGIS 4000RTP Manual User Manual

Page 28

Advertising
background image

98

SELECT

INITIATING

PREMISE CALL

KEY

## or **

99

SET MEMORY

TO FACTORY

DEFAULT

ERASE THE

MEMORY AND

RESET THE

SYSTEM TO

FACTORY

DEFAULT, THE

MASTER CODE

IS ALSO RESET

TO 0000

hear “Three Short Beep”.

Step 1

Entering The Programming

Mode: Press 0 and # simultaneously
then release.
If you are in the
programming mode, proceed to step 2.

Step 2

Enter the 4-digit Master

Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see Reset
Master Code.

Step 3

Enter 98 then #, you will

hear “One Short Beep”.

Step 4

Enter 0 to use # key or 1 to

use

∗∗ ∗∗ then press #, you will hear

“One Short Beep”.

Step 5

Enter another Function Code

to program another parameter other-
wise press

∗ to exit and you will hear

“Three Short Beeps”.

Step 1

Entering The Programming

Mode: Press 0 and # simultaneously
then release.
If you are in the
programming mode, proceed to step 2.

Step 2

Enter the 4-digit Master

Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see Reset
Master Code.

Step 3

Enter 99 then #, you will

hear “Two Long Beeps”.

Step 4

Enter 0 then # to cancel and

you will hear “One shor

t

beep” or 1

then # to clear the system’s database
and entire configuration to factory
default and you will hear “Three short
beeps”.

Step 5

Enter another Function Code

to program another parameter
otherwise press

∗ to exit and you will

hear “Three Short Beeps”.

Step 1

Pick up the phone and wait

for a dial tone.

Step 2

Press # # and you will hear

“One Short Beep”.

Step 3

Press # and you will hear

“One Short Beep”.

Step 4

Enter the Function Code 98

then press #, you will hear “One Short
Beep”.

Step 5

Enter

0 = to select ## or
1 = to select

∗∗

then press #, you will hear “One Short
Beep”.

Step 6

Enter another function code

to program a different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three Short Beeps”.

It must be done locally at the
main lobby control panel.

Step 1

Call to the AeGIS 400RTP

system (you must know the system’s
phone number), you will hear: “One
Short Beep”,
the gate is locked. “Two
Short Beeps”,
the gate is unlocked.

Step 2

Press # then enter a valid

master code and you will hear:
“One Short Beep”, the master code

is accepted then press # and you will
hear “One Short Beep”.

“One Long Beep”, the master code

is rejected and the connection will be
disconnected.

Step 3

Enter the Function Code 98

then press #, you will hear “One Short
Beep”.

Step 4

Enter 0 (to select ##) or 1 (to

select

∗∗) then press #, you will hear

“One Short Beep”.

Step 5

Enter another function code

to program a different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three Short Beeps”.

It must be done locally at the
main lobby control panel.

Function

Local Programming

Premise Phone

Remote Phone

Pach and Company

Page 20

AeGIS 400RTP

Chapter 3. Programming