Checking the power supply setting, Connecting the power cable, Ontents – Avery ALS 256 User Manual

Page 34: Lectrical, Connections

Advertising
background image

30

C

ONTENTS

3.1 E

LECTRICAL

CONNECTIONS

ALS

20x
256

GB

Checking the power supply setting

ALS 256: A power supply setting is not re-
quired.

The ALS 20X Label Dispenser is suitable for
operation with a power supply of 230 V (AC) or
110 V (AC).

If you are unsure of what mains voltage your
local electricity supplier provides, refer to a
qualified service technician.

£

Check to see that the voltage that has been set
conforms to the local mains voltage.

[28] Permissible mains voltages for both positions on the voltage

selector switch.

Changing the voltage setting:

£

Make sure that the power cable is
disconnected.

£

Slide the switch [27A] to the respective
opposite position.

– Insert a small screwdriver into the groove

[27B]

and

move the red insert horizontally to the opposite stop
position (to the left in Figure

[27]).

Connecting the power cable.

£

Make sure that the power switch [29A] is set to ‘O’
(off).

£

Using the supplied power cable, plug the unit into a
socket connected to the mains supply.

For more information on fuses, see section
“Replacing fuses” on page 47.

Switch setting

Permissible mains voltage

115

100–120 V (AC)

230

200–240 V (AC)

[27] Voltage selector switch on the ALS 20X (set to 230 V in the

figure)

A

B

[29] Power cable (B) plugged in.

B

A

Advertising