I - start-up, Page 4 a) operating voltage source, C) y-connector with battery clips – Power Probe The Hook User Manual

Page 4: D) auxiliary ground lead, E) flashlight, F) sleep mode

Advertising
background image

H

O M

1

H

0 0

Page 4

a) Operating Voltage Source

The PPH is designed for use in 12 to 48 VDC electrical sys-

tems and comes supplied with a 20 ft., 10-gauge coax cable

and 2 heavy-duty battery hook-up clips.

b) Connecting to the Vehicle’s Battery

(Voltage Source)

Connect the red clip to the positive terminal of the vehicles

battery source and the black clip to negative or ground. The

PPH start-up tone will sound and the indicator light on the Y-

Connector with Battery Clips will illuminate. This tells you that

the Hook is connected correctly and the internal fuse of the

Y-battery-clip-connector is working properly.

c) Y-Connector with Battery Clips

The Y-Connector with Battery Clips has a safety fuse built into

it. The built-in fuse will blow in the event the 10-gauge coax

power cable gets clamped or pinched in a door or hood caus-

ing a short circuit.

Note: If the Y-Connector with Battery Clips does not light when

properly connected to the voltage source, you probably have a

damaged 10 gauge coax power cable. It is recommended that

the cable be inspected and tested before replacing a new Y-

Connector with Battery Clips.

Contact your distributor or Power Probe, Inc. for a replacement.

d) Auxiliary Ground Lead

The auxiliary ground lead provides ground to circuits and

components that are not already connected to ground. It also

serves as the negative lead for resistance testing.

To test the auxiliary ground lead, contact the probe tip and the

auxiliary ground lead together. The Green LED on the display

should light. This shows that the auxiliary ground lead is work-

ing properly.

If the green LED does not illuminate, check the replaceable 25

amp fuse in the auxiliary ground lead. The fuse is a protection

in the event the lead is inadvertently contacted with battery

positive.

e) Flashlight

Flashlight is a standard feature on the PPH. The bright LED

Flashlight is always ON making it possible to probe under

dashboards and in dark areas.

f) Sleep Mode

The PPH goes to sleep after 10 minutes of inactivity and you

will see SLEEPING in the display. The Flashlight and the LCD

backlight will turn off. To wake it up, just press any button or