Whenever the alarm is operating, the green Power LED flashes every 30
seconds to indicate the unit is monitoring for CO. If the alarm senses
dangerous levels of CO, the red Alarm LED will flash and the alarm will
emit an audible alarm pattern.

5. Model KN-COB-B-LS-UK(900-0233) Operating

Characteristics

Operating and Alarm Characteristics

Function

LED Display

Alarm Sound

Unit Status

Recommendation

Normal
Operation

Green LED
flashes every 30
seconds

None

Normal DC
operation (sensing
no CO) and with
good batteries

None

Carbon
monoxide
alarm

Red LED flashes
with beeps.

Repeating
ON/OFF beeps

Alarm condition.
Dangerous
concentrations of
CO detected

Refer to “What to do
When the Alarm
Sounds” (inside front
cover)

Low
battery

Red LED flashes
every 30 seconds

One quick
beep every
30 seconds

Batteries need to be
replaced

Replace all three AA
batteries

Error /
service
alarm

Red LED flashes
every 30 seconds

One quick
beep every
30 seconds

Unit is in error
condition

Error

Red LED
constantly on

Constant
alarm

Very low battery or
unit malfunction

Replace battery.
If condition continues,
unit has
malfunctioned.
Replace immediately.
Unit will not respond
to CO

Normal
Test/Reset
function

Red LED flashes
with beeps.
Green LED on

Repeating
ON/OFF beeps

Normal operation
when Test/Reset
button is pressed

CO not detected.
Alarm for test
purposes only

End of
unit life
indicator

Red LED flashes
twice every 30
seconds

Two quick
beeps every
30 seconds

End of unit life

Replace unit
immediately. Unit will
not respond to to CO