Operating Instructions

11

70400101

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Figure 4

Single Drop Control

SD and SX Control Suffixes

1. Select HIGH, MED, LOW or NO HEAT by

turning the temperature knob.

2. Insert the coin(s) in the coin slot.
3. Press START button to start tumbler.

IMPORTANT: To stop the tumbler at any time
during the cycle, OPEN DOOR. To restart the
tumbler, CLOSE door and press START button.

NOTE: If display show an error code, refer to Error
Codes
section.

4. When the cycle is complete, open door and

remove the laundry.

NOTE: This machine includes an extended tumble
feature. Starting 20 minutes after a cycle ends, the
cylinder will tumble for two minutes every hour
without heat, up to 18 hours or until door is
opened.

Preliminary Control Information

Power-Up Mode

When power is applied to the tumbler the control will

enter Ready Mode, unless a cycle was in process prior

to a disruption of power. If a power disruption is less

than 5 seconds, with a cycle in process, the control

will enter Run Mode once power is restored and

continue the cycle. If a power disruption is more than

5 seconds, with a cycle in process, the control will

enter Start Mode once power is restored.
If the dry time dipswitch settings have not changed

from the factory default, the IN USE LED will flash

two to five times, depending on model.

Ready Mode

In Ready Mode, the control waits for the vend to be

satisfied before entering Start Mode.

Start Mode

In Start Mode, the vend has been satisfied, but the

Start button has not been pressed. The IN USE LED

will be lit. The timer will not count down until the

Start button is pressed.

25

C

Advertising