Operating Instructions

70400101

12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Run Mode

In Run Mode, the control is running a cycle. The IN
USE

LED is lit.

Door Open Mode

In Door Open Mode, the control turns off the heater

and motor when the door is opened during a run

cycle. The timer will continue to count down time

and the IN USE LED is lit.

End of Cycle Mode

In End of Cycle Mode, a cycle is complete and the
IN USE

LED is off. The control remains in this

modeuntil the door is opened or additional vend has

been satisfied

Topoffs

Any time the control receives a coin drop pulse during

a cycle it will add the programmed dry time to the time

currently remaining in the cycle. The maximum cycle

time is 99 minutes, the control will not add time

beyond 99 minutes. The cool down time will not

change.

If the control receives a coin drop pulse during cool

down the IN USE LED will flash briefly to indicate the

coin input, the machine will exit cool down and it will

start heating. The cycle time will be equal to the

programmed dry time

Temperature Selector Switch

For five minutes after the control is powered up, there

is a diagnostic feature that allows the temperature

selector switches to be tested.
When the temperature selector is changed, the new

setting is displayed by flashing the IN USE LED as

follows:

High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash

NOTE: To change dipswitch settings refer to
Installation Manual
.

Error Codes

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the tumbler is properly grounded.

W002

WARNING

Display

Definition

Corrective Action

AF (flashing)

Airflow switch opened/closed 5 or
more times in a running cycle.

Check airflow switch. Replace if inoperative.