SPP Pumps Instream User Manual

Page 15

Advertising
background image

Operators Instructions for

Instream Centrifugal Pumps

Manual No/Rev

W23-001E / 8

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 15 of 16

9.2 Standard Metric Nut and Bolt Torque Recommendations

This information is for reference only. The user must check that the torque figures listed here are applicable to the
fasteners used. Nuts and bolts should be neither under nor over tightened.

Grade of Bolt

Approximate Torque (Nm) for Bolt Diameters:

M5

M6

M8

M10

M12

M16

M20

M24

M30

M36

4.6

2.7

4.5

11

22

38

95

185

320

633

1110

8.8

6.9

11.7

28

56

98

244

476

822

1634

2855

10.9

9.4

15.9

38

77

134

332

646

1120

2223

3885

12.9

11.2

19.1

46.4

92

160

397

775

1342

2666

4660


Note:
These torque figures are approximate, and for un-plated fasteners only. No allowance has been made for
special finishes or lubricants, washers or mating surfaces.

Bolt and Nut Grade Combinations

Grade of BOLT

4.6

8.8

10.9

12.9

Note: It is permissible to fit higher grade
nuts than recommended.

Grade of NUT

4

8

12

12


Grade Identification

BOLTS & NUTS - Grade 4.6

BS4190 (ISO272, 885, 888 & 4759/1). Grade marking is optional.
Normally there will be no mark other than the 'M' thus:

BOLTS - Grade 8.8

BS 3692 (ISO272, 4759/1). Grade
marking is mandatory, may also
have trade marks

NUTS - Grade 8

Indented marks as a clock face,
dot at 12.00, bar at 8.00,
indicates grade 8 nut.

High Strength Friction Grip Bolts & Nuts

BOLT

NUT

BOLT

Grade10.9

NUT

Grade 12

Maintenance Record

Date

Summary of maintenance & repairs done - replacement parts fitted etc:

Installed & Commissioned

First Oil Change (after 200 hours running)