Operators Instructions for

Instream Centrifugal Pumps

Manual No/Rev

W23-001E / 8

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 9 of 16

Where new joints are made, correct gasket
thicknesses must be maintained.

After reassembly the rotor must turn easily by
hand, otherwise premature pump failure may
occur.

6.3.2 Dismantling

Introduction


In general when pumps are dismantled,
inspected and/or replacement parts fitted, the
work is undertaken for one of the following
reasons.

a)

Preventative Maintenance:

Because the time for the regular periodic
inspection

has

become

due.

Planned

inspection and maintenance at pre-determined
intervals is a sound insurance against a forced
shutdown due to a failure at a more
inconvenient time.

b)

Remedial Maintenance:

Perceptible fall off in pump performance
affecting capacity and pressure or: failure of
mechanical seal or: excessive and continuous
vibration with persistent noisy operation.


The extent of dismantling required will depend
upon the reasons above.


In the case of preventative maintenance,
inspections are done at preselected times and
the

pump

usually

requires

complete

dismantling, so that all parts can be cleaned,
examined and measured for wear.

The extent of dismantling for remedial
maintenance will depend upon the cause of
failure and needs only to reveal the source of
the trouble.


When dismantling the pump, the volute casing
can remain mounted in the pipework. Tightly
shut both the inlet (if fitted) and outlet valves
and

disconnect

any

external

service

connectors.


On pumps using motors with frame sizes up to
and including D180M, it is NOT advisable to
remove the stub shaft under normal pump
maintenance conditions. On these pumps, the
stub shaft (21.11) is attached to the motor
using

a

collet

nut

and

grub

screw

arrangement. It requires special tools and
fixtures to remove and reassemble correctly. It
is recommended that this be performed only
by a trained SPP Pumps Ltd. Service
Engineer or an authorised SPP Pumps Ltd.
dealer/agent.


To dismantle pump, proceed in the following

sequence:


1.

Drain liquid from the casing, remove plug
(90.31).


2.

Unscrew nuts (92.0) on volute casing studs
(90.2)


3.

Motor (80.1), complete with supporting frame
(34.4) and casing cover (16.1), can now lifted
clear of volute casing (10.2).

Note! On the pumps fitted with a clamped casing

cover, care must be taken not to disturb the
joint between the casing cover (16.1) and
supporting frame (34.4).


4.

Lay the pump down horizontally taking care
not to damage the impeller.


5.

The impeller (23.0) is now clear of casing
(10.2) and can be removed by unscrewing the
impeller nut (92.2) in a counter clockwise
direction and removing the lockwasher (93.0).


6.

Remove the impeller key.


7.

With the impeller (23.0) and key (94.01)
removed, the shaft sleeve (52.3) complete
with the rotating element of the mechanical
seal (43.3) can now be slid off shaft (21.11).


8.

The seal should be carefully examined and if
worn, should be replaced. Do not remove the
rubber or elastomer bellows from the sleeve,
unless necessary for examination or cleaning.


9.

To remove the stationary element of the
mechanical seal:


a)

For pumps fitted with bolted casing cover,
remove stud nuts (92.02) from casing cover
studs (90.22).


b)

For pumps, fitted with a clamped casing cover,
and to continue dismantling pumps fitted with
bolted casing covers:


Remove the casing cover (16.1), complete
with the stationary element of mechanical seal
(43.3) from the supporting frame (34.4) by
carefully prising apart with screwdrivers or
similar tools which fit in recess between the
casing cover (16.1) and the supporting frame
(34.4).


Care must be taken to ensure that the casing
cover (16.1) does not damage the shaft (21.1).


6.3.3 During and After Dismantling

1.

All parts must be carefully cleared and tested
for wear. Recondition or replace parts where
necessary.

Advertising