General information and safety instructions – SPP Pumps Unistream User Manual

Page 3

Advertising
background image

Operators Instructions for

Unistream Centrifugal Pumps

Manual No/Rev

W21-002E / 10

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 3 of 24

CONTENTS

Section ........................................................ Page
1

General Information & Safety

Instructions ............................................ 3

2

Transport Handling and Storage ........... 4

3

General Description ............................... 5

4

Assembly and Installation ...................... 5

5

Commissioning and Operation .............. 7

6

Maintenance and Service ...................... 9

7

Faults and Remedial Action ................. 14

8

Pump Details: ...................................... 14

8.1 Pump Dimensions & Weights ........... 15
8.2 Pump Sections and Parts Lists ......... 15

8.3 Pump Connections ........................... 20

9

Additional Information .......................... 22

10

Bolt Torque Recommendations ........... 23

11

Spares and Service ............................. 24

Manufacturers Information:

(Where applicable)

Seal & Seal System .......................... Appendix I

Coupling .......................................... Appendix II
Electric Motor .................................. Appendix III

Introduction

This manual gives the safety, installation, operation
and maintenance instructions for pumps in the SPP
Pumps UNISTREAM range of horizontal, end
suction, centrifugal pumps for general and
industrial use

Pumps may be identified by the SPP Pumps code
typically in the form 'KP04E' or by the Equivalent
Standard pump code typically in the form '40/26'.

This manual applies to the following pump types:

Pump Size Code

Type Suffix Letter

SIZE

Code

Delivery

Branch

Dia.

mm.

Standard

Size

Code

TYPE

Suffix

Nominal

Impeller

Dia.

mm.

Standard

Size

Suffix

KP03

32

32/**

B

125

**/13

KP04

40

40/**

C

160

**/16

KP05

50

50/**

D

200

**/20

KP06

65

65/**

E

250

**/26

KP08

80

80/**

F

315

**/32

KP10

100

100/**

G

400

**/40

KP12

125

125/**

V X Y These pumps are.

KP15

150

150/**

& Z

non-standard

Use this table to convert the pump type code into
the equivalent standard code to obtain information
for your pump from the manual. Note, for pump
types AV03N, KP08V & Y, KP10X & Y, KP12X & Z,
& KP15Y, please refer to separate manuals W21-
003E and W21-004E

1. General Information and Safety
Instructions

The products supplied by SPP Pumps Ltd. have
been designed with safety in mind. Where hazards
cannot be eliminated, the risk has been minimised
by the use of guards and other design features.
Some hazards cannot be guarded against and the
instructions below MUST BE COMPLIED WITH for
safe operation. These instructions cannot cover all
circumstances; YOU are responsible for using safe
working practices at all times.

1.1

SPP Pumps Ltd. products are designed for
installation in designated areas, which are to
be kept clean and free of obstructions that
may restrict safe access to the controls and
maintenance access points.

A pump nameplate is fitted to each unit and
must not be removed. Loss of this plate
could make identification impossible. This
in turn could affect safety and cause difficulty
in obtaining spare parts. Should accidental
loss or damage occur, contact SPP Pumps
Ltd. immediately.

1.2

Access to the equipment should be
restricted to the personnel responsible for
installation, operation and maintenance and
they must be trained, adequately qualified
and supplied with the appropriate tools for
their respective tasks.

1.3

SPP Pumps Ltd. requires that all personnel
that are responsible for installation, operation
or maintenance of the equipment, have
access to and study the product instruction
manual BEFORE any work is done and that
they will comply with all local and industry
based safety instructions and regulations.

1.4

Ear defenders should be worn where the
specified equipment noise level exceeds
locally defined safe levels. Safety glasses or
goggles should be worn where working with
pressurised

systems

and

hazardous

substances.

Other

personal

protection

equipment must be worn where local rules
apply.

1.5

Do NOT wear loose or frayed clothing or
jewellery that could catch on the controls or
become trapped in the equipment.

1.6

Check and confirm that the manual is the
relevant copy by comparing the serial
number on the identification plate with that
on the manual.

Advertising