Section 5: TROUBLESHOOTING


5.10 Vacuum

Problems

Leakage, contamination and unusual outgassing are the general causes of problems with poor vacuum.

To operate at maximum effi ciency a system must be thoroughly clean. If the system is completely

clean and free from leaks, and unwarranted vacuum problems still exist, the pump should be checked.

A simple criterion for the condition of the pump is the determination of its maximum vacuum capability.

This can be accomplished by blocking of the intake and reading the vacuum level on the gauge

(See Section 2.8).

5.11 Troubleshooting

Guide

Section 6: SPECIFICATION


6.10 Pump

Specifi cations

Model 2585

Free Air Displacement

7.1 CFM @60Hz
(201 L/min. @60Hz)

10.0 M3 @50Hz
(168 L/min. @50Hz)

Ultimate Pressure

60 Torr, (80mbar)

Maximum Vacuum

27.6 In.Hg.

Motor Horsepower

1/3 (250 watts)

Tubing needed

I.D. 3/8”, (10mm)

Intake & Exhaust Thread

3/8 NPT

Weight

22.5 lbs (10.3 Kg)

Overall Dimensions

17 x 7.5 x 12 Inches

43.2 x 19.1 x 30.5 cm

Poor

Pumping

Speed

Poor

Vacuum

Loud

Unit

Possible Cause

Corrective Action

X

X

X

Damaged Valves

Replace fl apper Valves

X

X

X

Debris in Valves

Remove debris and check for valve damage

X

X

X

Damaged Gasket

Replace Gasket

X

X

X

Loose Head Screw

Tighten Head Screw

X

X

X

Loose Fitting

Tighten Fitting

Advertising