2.20 Electrical Power
2.21 Power Source Review

Review the power source and the voltage rating on the units serial number tag to be sure they agree in

voltage, phase and frequency. Serious damage may occur to the system if it is connected to an im

proper voltage. All Welch systems must be grounded. Grounding reduces the risk of electric shock

in the event of an electrical short circuit. The plug must be plugged into an outlet properly grounded.

Consult your local electrical codes if you have doubts.

2.22 Overload

Protection

The motor manufacturer makes motor thermal overload protection availeble as an aid to minimize mo-

tor failure. Overload protection is a standard feature on both 50/60Hz single-phase motors. The motors

have automatic overload protection. Automatic reset protection is designed to reset itself after a

predetermined cooling period. If the fault to the drive remains unaltered, the motor will cycle on and off

until fault is corrected.

2.23 Identifi cation Symbols





2.24 Grounding

Instructions

This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk

of electric shock by providing an escape wire for the electric current. This product is equipped with a

cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is

properly installed and grounded in accordance with all local codes and ordinances.

This adapter shown in Figure #1 B and C is not acceptable in Canada.
















If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either fl at

blade terminal. The wire with insulation having an outer surface that is green with or without yellow

stripes is the grounding wire.

Check with a qualifi ed electrician or serviceman if the grounding instructions are not completely

understood, or if in doubt as to whether the product is properly grounded. Do not modify the plug

provided; if it will not fi t the outlet, have the proper outlet installed by a qualifi ed electrician.

DANGER

Improper installation of the grounding plug

can result in a risk of electrical shock.