Cal 2 p015 – Electronics International FL-1 User Manual

Page 15

Advertising
background image

13

Note: If you want to manually program the Sensor Counts, push and hold the Enter Button at the

back of the FL-1 (with the Sensor Counts displayed and not blinking) until the thousands digits
starts to blink.

To increase the count of the blinking digit, move the Selector Switch from the center position to

the right.

To decrease the count of the blinking digit, move the Selector Switch from the center position to

the left.

To blink the next digit to the right, tap the Enter Button on the back of the FL-1.

To exit the manual programming of the Sensor Counts, lock the Sensor Counts into the display

and stop the blinking of a digit, push and hold the Enter Button for 3 seconds.

9. To advance to the next calibration point, move the selector switch to

the left position, push and hold the Enter Button on the back of the
unit until you see “CAL2” in the display. All of the calibration data
for calibration point 1 has been stored to permanent memory.

10. Fill the tank to the fuel level indicated on your calibration chart for

the next calibration point.

11. Place the Selector Switch to the center position. The FL-1 will

display the last programmed fuel level for this calibration point. The display will show something
like “P015” or maybe “F015”. A “P” would indicate this is a partial fuel level (not the full fuel
level). An “F” would indicate this is the full fuel level for the tank and the last cal point. The "015"
is the fuel level for this cal point.

12. To program (change) the fuel level for this calibration point, push

and hold the Enter Button on the back of the FL-1 for 3 seconds.
The far left letter (“P” or “F”) will be blinking. To change this
letter, move the selector switch to the left or right.

If this calibration point is for a partial fuel level (not the full fuel

level), select “P”. If this calibration point if for the full fuel level
(the last cal point) select “F”.

Note: The programmed fuel level must increase for each calibration point.

Note: The programmed fuel level must increase for each calibration point.

Note: The programmed fuel level must increase for each calibration point.

Note: The programmed fuel level must increase for each calibration point.

Note: The programmed fuel level must increase for each calibration point.

To increase the count of the blinking digit, move the Selector Switch from the center position to

the right.

To decrease the count of the blinking digit, move the Selector Switch from the center position to

the left.

To blink the next digit to the right, tap the Enter Button on the back of the FL-1.

To exit the programming of the fuel level for this calibration point and stop the blinking of a digit,

push and hold the Enter Button on the back of the FL-1 for 3 seconds.

CAL 2

P015