4.7.1 Explanation of SAN Unit I/O

INPUT SIGNALS

S

A

N

2

P

in

#

S

A

N

3

P

in

#

SIGNAL NAME

DESCRIPTION

1

1 STOP

Emergency Stop Input (Normally Closed)

This signal must be active (on) for controller operation. When this
signal is inactive (off), controller operation will stop, and input/outputs
will be disabled.

AVAILABLE IN STAND ALONE OPERATION ONLY,

2

2 RESET

Reset Input (Normally Open)

When active (on), this signal will clear all fastening data, and discrete
outputs. A Zero Check of the torque transducer will be completed.
During the Zero Check, the ACCEPT or REJECT lamp will light to in-
dicate the result of the Zero Check. If the System has been disa-
bled by an Abnormal output, the System will not return to normal op-
eration until the Abnormal condition has been corrected, and this sig-
nal has been input for 200~500 milliseconds.

Do not input this signal between cycles, due to the potential for data
loss.

AVAILABLE IN STAND ALONE OPERATION ONLY,

3

3 REVERSE

Reverse Spindle Rotation Input (Normally Open)

The spindle will rotate in an opposite direction for as long as this sig-
nal is activated (on) and maintained. The Reverse input functions
the same as the reverse push-button on the front of the SAN unit.

AVAILABLE IN STAND ALONE OPERATION ONLY,

4

4 START

Start Cycle Input (Normally Open)

The Start input automatically resets the previous cycle, clears all data
to zero, and initiates the next fastening cycle. The Start input requires
a pulse of 200~500 milliseconds if the SAN Unit DIP switches are set
up for AUTOMATIC Start input. If the SAN Unit DIP switches are
set up for DEADMAN (hand-held operations) input, the Start input
must be maintained "on" for the entire cycle.

AVAILABLE IN STAND ALONE OPERATION ONLY,

5

5 BYPASS

Spindle Bypass Input (Normal Open)

When active, all functions of this spindle are bypassed, and the By-
pass output is active. (Available in both Stand Alone & Multi set-
up)

6

6 SYNC COMMON

Input common signal for input 8 "SYNC" signal.

AVAILABLE IN STAND ALONE OPERATION ONLY,

7

7 SYNC COMMON

Input common signal for input 8 "SYNC" signal.

AVAILABLE IN STAND ALONE OPERATION ONLY,