Blagdon Pump B75 Metallic User Manual

Page 20

Advertising
background image

Blagdon Pump • A Unit of IDEX Corporation • R79 Shannon Industrial Estate • Co Clare, Ireland • Tel: +353 (0) 61 471933 • Fax: +353 (0) 61 475046

www.blagdonpump.com • E-Mail: [email protected]

x75mdl1sm-rev0812

Page 18

Air Operated Double Diaphragm Pump 6/05

Page 18

ACTUATOR PLUNGER SERVICING

To service the actuator plunger first

shut off the compressed air supply,
bleed the pressure from the pump, and
disconnect the air supply line from the
pump.

Step #1: See PUMP ASSEMBLY

DRAWING.

Using a 1/2" wrench or socket,

remove the four capscrews (items 11).
Remove the air inlet cap (item 8) and
air inlet gasket (item 20). The pilot valve
assembly (item 4) can now be removed.

Step #2: Inspect the actuator

plungers.

See ILLUSTRATION AT RIGHT.
The actuator plungers (items 30) can

be reached through the pilot valve cavity
in the intermediate assembly (item 5).

Remove the plungers (item 30) from

the bushings (item 7) in each end of
the cavity. Inspect the installed o-ring
(items 26) for cuts and/or wear. Replace
the o-rings if necessary. Apply a light
coating of grease to each o-ring and
re-install the plungers in to the bushings.
Push the plungers in as far as they will
go.

To remove the bushings (item 7),

first remove the retaining rings (item 31)
by using a flat screwdriver.
NOTE: It is recommended that new
retaining rings be installed.

Step #3: Re-install the pilot valve

assembly into the intermediate assembly.

Be careful to align the ends of the

stem between the plungers when
inserting the stem of the pilot valve into
the cavity of the intermediate.

Re-install the gasket (item 20), air

inlet cap (item 8) and capscrews (item
11).

Connect the air supply to the pump.

The pump is now ready for operation.

ACTUATOR PLUNGER SERVICING

27

7

32

31

5

Read these instructions

completely, before in-

stallation and start-up. It

is the responsibility of

the purchaser to retain

this manual for reference. Failure to

comply with the recommendations stated

in this manual will damage the pump, and

void factory warranty.