Trouble shooting – Darex XT-3000A User Manual

Page 88

Advertising
background image

86

The unit stopped working and the screen

displays “Sharpening Interrupted”:

This message will appear if the user

presses the “Stop” button during sharpen-

ing. It will also appear if the controller de-

tects a large load on the chuck turning

motor. This is typically caused by dirt or

grit accumulating on the Chuck Body,

Chuck Tube Liner, or the Cam Follower

Assembly. Turn the machine off and per-

form the standard maintenance procedures

listed on pages 29 & 30. Restart the ma-

chine and see if it runs without interrup-

tion. If the controller continues to show

this message, call Darex customer service

for assistance.

The display does not come on when I

plug the unit it:

The auto controller receives its power

through the AC plugs in the rear of the

unit. Make sure there is power to the out-

let you are using.

Make sure the wiring on the back of the

unit matches that of the user manual

(power comes in to the controller, and

both pigtails are firmly seated between the

controller and the XT unit).

Try unplugging and re-plugging these

cords to ensure they are well seated.

Finally, make sure the on/off switch on the

XT-3000 machine is powered on. The dis-

play will not come on until you power up

the XT-3000. If unsuccessful, call Darex

customer service for assistance @ 800-

547-0222.

The unit powers up, the display is on, but

pushing the “Start” button to sharpen

nothing happens:

There is a cord that connects the sharpen-

ing port to the Auto Controller/Display,

see page 12. Be sure that the 5 pin DIN

connector on this cord is firmly seated into

the connector on the Controller/Display,

paying careful attention to cord/connector

orientation. Important: See information

on page 67. Inspect the cable, coming from

the controller to the sharpening port,

for damage.

If the optical switch in the Sharpening

Fixture is faulty, call Darex customer

service for assistance.

Check the small cable coming from the

sharpening port to the Gear Motor.

Finally, remove both covers on the Gear

Motor and Gear located on the Sharpening

Fixture. Verify the Drive Gear is secured to

the Gear Motor.

The unit powers up and runs the sharp-

ening system, but the vacuum does not

come on:

The vacuum receptacle for the Auto sharp-

ening system is located on the back of the

Controller/Display housing, see page 14.

Make sure this connector is firmly seated.

The connector is fused with two 8A time

delay fuses (1.6A on the 230V interna-

tional model). Make sure these fuses are

intact. If a fuse is found to be blown, then

both fuses should be replaced with the ap-

propriate capacity. You can find the part

numbers for these fuses listed on page 26.

Note: Using fuses not supplied by DAREX is

not recommended and may cause damage to

the Controller/Display.

If the grind motor starts but the Auto

Display is off:

The internal relay may be defective. This

can be detected by checking for voltage at

the vacuum output receptacle with an

electrical meter.

Trouble Shooting

Advertising
This manual is related to the following products: