Kf series, General pump – General Pump KF Owner Manual User Manual

Page 6

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

KF SERIES

Page 6

7. GENERAL INFORMATION ABOUT PUMP

USE

The KF pump has been designed to pump fresh and

filtered (360 micron max.) water at room temperature.

Special versions are available for pumping water up to
185oF and for reverse osmosis units.

7.2 Max flow and pressure ratings

The performance data indicated in the catalog and on the

rating plate refer to the maximum performance of the

pump. The use of the pump below the rated performances

does not allow the drop in power absorbed to be balanced

by altering the pressure or volume of the pump above its

maximum value.

7.3 Lowest operating RPM

The lowest operating speed of the crankshaft for all KF

pumps (all versions) is 500 RPM (on crankshaft).

8. CONNECTIONS AND PLUGS

KF pumps are provided with (Fig. 3):

1 - 2 inlet ports IN Ø 1-1/2” NPT

Suction line connection to either inlet port is

acceptable, the port not being used should be

sealed with the correct plug.

2 - 2 outlet ports OUT Ø 1” NPT

3 - 3 auxiliary ports Ø 1/2” NPT (usually used for

pressure gauge)

7.1 Water temperature

The water temperature is critical for the pump

life: the higher the water temperature, the

more likely it is to create cavitation, resulting in

premature seal and valve failures.

For such conditions, use HT series pumps.