Kt series, General pump – General Pump KT User Manual

Page 9

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

KT SERIES

7. OPERATING INSTRUCTIONS

The KT pump was designed to operate with filtered water (see paragraph 9.7), in environments that are not
potentially explosive and at maximum temperature of 104

0

F (40

0

C).

Other fluids may be used only upon the approval of The Customer Service Department .

7.1 WaterTemperature
The max water temperature is 104

0

F (40

0

C).However, it is possible to use the pump at temperatures of up

to 140

0

F (60

0

C) for short periods of time. In this case we advise consulting the Customer Service

Department.

Page 9

Ref 300941 Rev.A

03-14

7.2 Max Flow Rate and Pressure Values

The performance values indicated in the catalog refer to the maximum performance of the pump. Regardless of the power

used, pressure and maximum RPM values indicated on the plate may not be exceeded unless expressly authorized by the

Customer Service Department.

7.3 Lowest RPM

Any RPM value different from what is indicated in the performance table (see chapter 5) must be expressly authorized by

the Customer Service Department.

7.4 Recommended Lubricant Oil Types & Manufacturers
The pump is delivered with lubricant oil compliant with room temperatures ranging between 32

0

and 89.6

0

F (0

0

and

30

0

C ). Some recommended lubricant types are indicated in the table below; these lubricants are treated with additives

in order to increase corrosion protection and resistance to fatigue. As an alternative, Automotive SAE 85W-90 gearing

lubricants may also be used.

BRAND

TYPE

GENERAL PUMP

SERIES 220

ARAL

Aral Degol BG220

BP

ENERGOL HLP 220

CASTROL

Hyspin VG 220, Magna 220

ELF

POLYTELIS 220

ESSO

NUTO 220

FINA

Cirkan 220

FUCHS

RENOLIN 220

MOBIL

DTE OIL BB

SHELL

TELLUS C 220

TEXACO

RANDO HD 220

TOTAL

CORTIS 220

Check the oil level by using the oil level dipstick (1), fig. 3.

Refill if necessary to top off level. Correct oil level

inspection is done with the pump at room temperature; oil

is changed with the pump at working temperature, by

removing the oil dipstick (2), fig 3, and then the drain plug

(3), fig. 3.

Checking and changing oil is to be carried out as indicated

in the table in fig. 14,Chapter 11. The amount required is

304 oz. (2 liters).

Advertising