GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Page 11

The pump’s shaft (PTO) must not be rigidly connected to the motor unit.

The following transmission types are suggested:

• Flexible joint

• Cardan Joint (please respect the maximum working angles indicated by the manufacturer)

• Belts; for correct application, please contact the Customer Service Department.

9. PUMP INSTALLATION

9.1 Installation

The pump must be installed in a horizontal position using the M16 threaded support feet.

Tighten the screws with a torque of 200 Nm (147.5 Ft-Lb)

The base must be perfectly flat and rigid enough as not to allow bending or misalignment on the pump coupling and

axis/transmission due to torque transmitted during operation.

Two lifting brackets are mounted on the pump for easy installation, as per the figure below.

Replace the oil filling hole closing service plug positioned on the rear casing cover with the

plug with oil dipstick. Check the correct quantity.

The dipstick must always be reachable, even when the unit is assembled.

The brackets are sized soley for pump lifting and therefore are absolutely not permitted for use

of additional loads.

Ref 300790 Rev.D