GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Page 15

With the pneumatic adjustment valve:

The filter must be installed as close as possible to the pump, should allow easy inspection and have the following

characteristics:

1. Minimum capacity 3 times greater than the pump’s rated flow value.

2. Filter port diameters must not be smaller than the pump inlet ports.

3. Filtration degree ranging between 200 and 360 µm.

In order to guarantee correct pump operation, it is important to plan periodical cleaning of the filter

depending on actual pump usage, water quality and actual clogging conditions.

9.8 Outlet Line

To obtain a correct delivery line, please comply with the following installation instructions:

1. The internal diameter of the hose must allow to guarantee correct fluid speed; see digram in paragraph 9.9

2. The first section of the hose connected to the pump must be flexible in order to isolate pump vibrations

from the rest of the system.

3. Use high pressure hoses and fittings that guarantee wide safety margins in any working condition.

4. Install a safety valve on the delivery line.

5. Use pressure switches suitable for the pulsating loads typical of plunger pumps.

6. In the design phase, take into proper account the pressure drop along the line, since this causes a reduction in

usage pressure with respect to the value measured at the pump.

7. If the pump pulsations are harmful for particular applications, install an appropriately sized pulsation dampener on

the outlet line.

Ref 300790 Rev.D