fountains will keep some amount of ice open through

the winter. However, when the water is thrust into

the air, it is exposed to the colder air temperatures

longer and can actually make ice thicker on the pond/

lake. Storage over winter is best in a location that is

out of the sun and cool, but above 32

O

F. When storing

units during the offseason, it is important to store them

upside down if they are going to be sitting for long

periods of time. Units that sit upright on a shelf for

many months, or even years have a greater likelihood

of seals drying out. Storing upside down will ensure

oil is lubricating the seals and prevent drying.

CLEANING: Fountains should be removed from the

water at least once per year (at the end of the season

in cold climates) to clean the exterior of the system,

especially the stainless steel motor housing (can). The

motor housing is the surface that dissipates heat into

the water and any algae, calcium, etc. build-up will be-

come an insulator that blocks heat transfer. In warmer

regions it is recommended that the motor is removed

and cleaned at least two to three times per year de-

pending on conditions. In most cases a power washer

will be sufficient if the unit and algae are still wet.

SEAL AND OIL REPLACEMENT: This is a sealed

motor assembly and seals will wear out over time

(similar to brake pads on a car). Replacement of the

seals and a change of oil after three years may add

longevity to the operation of the motor, saving you the

cost of more expensive repairs. In warmer climates

where the fountain runs most or all of the year, it is

a good idea to replace seals more regularly than you

would need to in colder climates where the unit is

removed from the water for several months.

ZINC ANODE: A Sacrificial Zinc Anode is supplied

on the shaft for protection of the equipment from cor-

rosion and electrolysis. The zinc anode should be up-

dated (replaced) if reduced to half the original size or

if white in color. Corrosion from electrolysis is more

commonly associated with saltwater or brackish water,

but as a matter of precaution, it is important to periodi-

cally check the zinc anode in all installations (at least

every two to three months).

Seal replacement and all other repair services should

be performed by Kasco Marine or a Kasco trained

Authorized Repair Center. Any alterations or changes

made to Kasco units by an unauthorized source will

Maintenance Recommendations

** Under No Circumstances should anyone enter the

water while a fountain is operating. **

** Please keep the original box for maintenance ship-

ping. **

The following maintenance procedures can be utilized

to ensure many years of quality performance from

your Kasco Fountain and reduce the need for more

costly repair work.

PROPER INSTALLATION: Proper installation of

Kasco equipment will include a power source with

ground fault interruption (GFI). For Fountain models,

the C-25 control (120V) or C-85 (240/208V) included

with the unit have built-in ground fault interrup-

tion that is sufficient. Ground fault interrupters are

a safety feature that can also alert you to electrical

leaks in the equipment. It is extremely important to

test the GFI upon installation, each reinstallation, and

monthly thereafter to ensure proper operation. If you

have repeat, consistent trips on your ground fault, the

equipment should be disconnected and removed from

the water. The power cord should be inspected for

damage and you should call Kasco Marine at 715-

262-4488 for further instructions or email Kasco at

[email protected].

OBSERVATION: Operating equipment should be

observed on a regular basis (daily, if possible) for any

reduction or variation in performance. If a change

in performance is observed, the equipment should be

disconnected from power and inspected for any ma-

terial that may have clogged the system or wrapped

around the shaft of the motor, especially plastic bags

and fishing line. Even though Kasco Aerators and

Fountains are among the most clog-resistant on the

market, it is impossible to protect against all items that

can clog equipment and still maintain a flow of water.

These materials can be very damaging to the equip-

ment under continued operation and must be removed

as soon as possible. ALWAYS UNPLUG THE UNIT

BEFORE ATTEMPTING TO REMOVE CLOGS.

WINTER STORAGE: In regions where there is

significant freezing in the wintertime, the fountains

should be removed from the water to protect them

from the expansion pressure of the ice. In many areas,