Aube Technologies TH110-SP-P User Manual

Summary, Installation, Operating modes

Advertising
background image

MODEL TH110-SP-P

SUMMARY

OPTIONS SELECTION

• To change the temperature from °C to °F and back, maintain D button

pressed down as RESET button is being pressed on and released.

Then release D button.

• To change the time format from 24 hours to 12 hours and back,

maintain H button pressed down as RESET button is being pressed

on and released. Then release H button.
TO SET TIME AND DAY

• Press on D, H and M buttons to adjust time and day.

TO RECORD THE HEATING PROGRAMS

• Set the operating mode to AUTO. Use the P button to select

the program to be recorded or modified. Once the program is selected,

use H and M buttons to set time and

or

to select

temperature setting.
TO RECORD THE ECONO PROGRAMS

• Set the operating mode to ECONO. Use the P button to select

the program to be recorded or modified. Once the program is selected,

use D, H and M buttons to set time and day and

or

to select

temperature setting.
OPERATING MODES

• To select an operating mode, use MODE button.

AUTO:

runs the programs.

or

shows temperature setting

and can override temporarily your programming.

MAN:

maintains the selected temperature.

or

changes

temperature setting.

ECONO: maintains a temperature setting up to the user's

pre-programmed day and time.

or

shows

temperature setting.

NOTE: The "Problems and Solutions" section at the end of this user's guide will

help you to correct your problems during the installation.

This thermostat has been designed to operate with any installation

which has a RESISTIVE load not exceeding 4800 W (20 A) such as

electric baseboards, radiant ceilings and floors, electric convectors,

etc. It is not compatible with a low voltage controller used by a central

heating system.

Electricians or experienced technicians should install the thermostat.

This thermostat is designed to be used with a self-protected heating

system equipped with thermal cut off and circuit breaker.

INSTALLATION

Note:

All cables and connections must conform to the local

electrical code.

WARNING: Special CO/ALR solderless connectors must be used when

connecting with aluminum conductors.

Connect the rear thermostat wires to the power supply and to the electric heater

wires using solderless connectors for copper wires. See schematic diagram.
Push the excess wire back into the electric box to prevent interference with the

thermostat. Secure the thermostat using two (2) 6-32 screws 1 1/4 inches long.

Once the thermostat is properly installed, return power to heating system.

1) Connecting wires and mounting thermostat

2) Options selection
Some options have been factory set. Those default settings are:

The temperature is in °C and the time format is 24 hours.

2.1 Temperature displayed in °C or °F

To change the temperature from °C to °F and back, maintain D button pressed

down as RESET button is being pressed on and released.

Then release D button.

2.2 Time format displayed in 24 hours or 12 hours

To change the time format from 24 hours to 12 hours and back, maintain H

button pressed down as RESET button is being pressed on and released. Then

release H button.
3) Memory backup

In the event of a power failure, an internal circuit will maintain the program-

ming. An icon

will be shown on the display. The display will stay on for 15

minutes; beyond this period, the display will turn off. Only the time will have to

be set if power failure is more than six hours. The thermostat will return to the

same operating mode as set before the power failure.
4) First power-up

When power is applied for the first time, the dis-

play must show the day and hour as follows:

0:00 MO (Monday)

The active operation mode is the framed MAN

mode, the temperature setpoint is 20 °C (68 °F)

and the ambiant temperature is displayed.

If the display is different, maintain P button

pressed down as RESET button is being pressed

on and released. Then release P button.

OPERATING MODES

The thermostat displays the icon

when the heating system is on and

turns it off when the heating system is off.

The TH110-SP-P thermostat has three (3) operating modes:

AUTO, MAN and ECONO.

They are selected through the MODE button. On display, the active mode is

framed. The frame moves on to the next mode each time the MODE button is

pressed on.

The AUTOmatic mode runs in sequence (hourly)

the programs recorded by the user.

By pressing once on

or

, the display shows

the temperature setting. All subsequent pres-

sures will override your programming up to the

next program.

To see the weekday and weekend programs, select

the AUTO mode and press successively on P

button to see the programs appear on the display.

PARTS INCLUDED

- One (1) TH110-SP-P thermostat

- Two (2) 6-32 screws, 1 1/4 inches

- Three (3) solderless connectors

TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER

PANEL TO AVOID ELECTRIC SHOCK. Keep air vents of thermostat clean

and free from obstructions.

The MAN mode allows the user to override

the programming.

The first time the

or

is pressed on,

the temperature setting is displayed. For all

subsequent times pressed on, the temperature

setting will change 1 °C (1 °F).

720-110522-A

1/3

Advertising