Lanair 215 Gallon Tank With Bypass Regulator User Manual

Page 10

Advertising
background image

®

Section 3 - Plumbing Installation

QUESTIONS?... Contact Customer Service at 1-800-753-1601 M-F 8:00 am- 4:30 pm CST

10

1/2" Copper Tube

To By-pass

Regulator

P/N 8850

Brass Elbow

1/2" comp x 1/4

NPT

FIGURE 10

PLUMBING INSTALLATION -
By-Pass Regulator To Burner

1. Attach the 1/2" comp x 1/4" NPT brass elbow (P/N

8850) as indicated in Fig 10.

3. Install the remaining 1/2" copper tube between

the compression fittings of the by-pass regulator
and burner (see Figs. 7 & 10).
NOTE: Make sure all fittings are properly tight-
ened. Leaking fittings may cause delayed ignition
in the burner.

Tank Drain and Plug

1. Determine which side of the tank the drain will be on. On that side, install a 1/2" close nipple

(P/N 8186) to the drain hole (see Fig 11).

2. Install the 1/2" brass ball valve (P/N 8187) to the 1/2" close nipple. Install a 1/2" pipe plug (P/N 8185)

into the end of the ball valve (see Fig. 11).

3. Install a 1/2" pipe plug (P/N 8185) into the hole on the opposite side of the tank (see Fig.12).

4. Vent the tank in accordance to state and local codes.

FIGURE 11

FIGURE 12

P/N 8186
1/2" Close Nipple

P/N 8187

1/2" Brass Ball

Valve

P/N 8185

1/2" Pipe Plug

P/N 8185
1/2" Pipe Plug

Advertising