Ransburg – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual

Page 26

Advertising
background image

Vector R Series Cascade Applicators - Installation

Ransburg

22

Routing of Air and Fluid Hoses

Starting at the applicator, route the air hose along

the same path as the low voltage cable to the low

voltage control unit. The fluid hose can be run

with the low voltage cable and air hose or it can

be separate and run to the fluid source. Do not

expose the hoses to high temperatures (over

120°F) and/or conditions such as moving parts,

foot traffic, vehicle traffic, etc.

Prior to connecting the air hose to the low voltage

unit and the fluid hose to the fluid supply, adjust

the hose and low voltage cable position at the

applicator to relieve some strain on the low voltage

cable. To do this, perform the following procedure:

1. Disconnect the air hose from the applicator.

2. Position the air hose 1-inch (2.5cm) away from

the bottom of the handle.

3. Secure the air hose to the low voltage cable.

Secure the two together at one additional location,

about 12-16-inches (30-41cm) back.

4. With a wrench, reconnect and secure the air

hose to the applicator. (This should form a small

loop in the low voltage cable.)

5. Secure the fluid hose to the air hose and low

voltage cable as needed.

Adjust the length of the air hose to the low voltage

controller and install the fitting to the hose.

Air Hose Recommendation

Ransburg recommends using a 79547-XX air

hose assembly that may be ordered through

your authorized Ransburg distributor. This hose

performs best with the Vector to reduce air hose

stiffness along with weight reduction. Available

hose lengths are listed in "Accessories" in the

"Parts Identification" section of this manual.

Fluid Hose Recommendation

Ransburg recommends using a 79548 fluid hose

assembly. This assembly is made to specifically

fit the fluid fitting size engineered into the applica-

tor. This hose is available from your authorized

Ransburg distributor. Available hose lengths are

listed in "Accessories" in the "Parts Identification"

section of this manual.

†

Any user installed air hose must be rat-

ed for 100 psig (6.9 bar) working pressure

minimum.

C A U T I O N

!

Air and Fluid Hose Installation

The fluid inlet fitting for the Vector applicator is

3/8-18 NPSM(M). When installing a fluid hose,

tighten the fitting adequately to prevent any fluid

leaks. The air inlet fitting is 1/4-18 NPSM(M). When

installing the air hose, use a wrench to hold the air

inlet fitting on the Vector and tighten the air hose

fitting enough to prevent any air leaks.

†

Any user installed fluid hose used must

be rated for 100 psig (6.9 bar) working

pressure minimum.

C A U T I O N

!

†

When securing the air hose, fluid hose,

and low voltage cable together, take care

not to use items such as wire or anything

that might cut into the hoses or cable. If

wire ties are used, they should only be tight

enough to secure the cable and not so tight

that they might restrict fluid and air flow.

W A R N I N G

!

AH-06-01.13

Advertising