Ransburg, Troubleshooting guide, Vector r series cascade applicators - maintenance – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual

Page 54

Advertising
background image

Vector R Series Cascade Applicators - Maintenance

Ransburg

50

Blown fuse

Is the power turned on?

Is the atomizing air turned on?

Is the applicator triggered?

Is the applicator switch on?

Is the paint too conductive?

Faulty flow switch

Replace fuse.

Check power supply.

Check air regulator.

Check applicator trigger.

Check applictor switch.

Check conductivity of paint.

Replace flow switch.

TROUBLESHOOTING GUIDE

(Cont.)

General Problem

Possible Cause

Solution

ELECTRICAL (Continued)

Improper or No High

Voltage (Cont.)

Isolation System

Grounded Out

Failed fluid hose

Insolation stand or charged

equipment too close to ground

Replace fluid hose.

Provide adequate ground distance.

AH-06-01.13