Mma-303 direct/indirect charge - introduction, Specifications (continued) – Ransburg MMA-303 Direct_Ind Charge Atomizer A12870 User Manual

Page 14

Advertising
background image

MMA-303 Direct/Indirect Charge - Introduction

11

LN-9269-11.3

Mechanical (Continued)

Maximum Fluid Pressure Supply

Paint:

200 psi (1379 kPa)

Solvent:

150 psi (1035 kPa)

Fluid Flow Rate:

25-700 cc/min. (Maximum 300 cc/min. on 30mm Bell Cup)

Bell Cup Cleaning Time

(Internal/External):

2.7 sec. (approx.)

Color Change Time:

Dependent on system configuration, fluid pressures, fluid vis-

cosity, fluid line lengths, etc.

Speed Readout:

Magnetic pick-up, unidirectional fiber optic transmission

Bell Cup Replacement Time:

Less than 2 min.

Minimum Control Equipment

Requirements:

(Versions listed or higher)

MicroPak

LECU5004-11 (V.3.84)

Atomizer Module

A11925-00 (V.0.4)

I/O Module

A11435-00 (V1.4) (0.01V) (4-20 mA)

* Specifications and ratings based on testing at sea level standard conditions.

SPECIFICATIONS (Continued)

Advertising