MMA-303 Direct/Indirect Charge - Maintenance

LN-9269-11.3

80

Fitting Tool Fully Engaged

Gently slide the tubing into the manifold until
the thread of the fitting can be engaged in the
manifold. With the fitting tool fully engaged into
the slots of the fitting, tighten the fitting into the
manifold until the face of the fitting is flush with
the manifold. (See “Tighten Fitting Into Mani-
fold” figures and “Face of Fitting Flush with
Manifold” figure.)

Tighten Fitting Into Manifold

Tighten Fitting Into Manifold

Face of Fitting Flush with Manifold