Ransburg, Chart a probe resistance check, Rma-303 indirect charge - maintenance – Ransburg RMA Indirect A11600 User Manual

Page 55

Advertising
background image

Figure 18: High Voltage Cable Installation

A11343-03

A11343-02

133-147 megohms

209-231 megohms

Chart A

Probe Resistance Check

8 Probe *

8 Probe

Above 5000 ft.
W/In-Line Resistor
Sea Level

Ring

Type

Used At

(location)

Resistance

Reading

Part

#

>

When this electrode assembly is used,

you must use the 78442-00 In-Line Resis-

tor Assembly for the 74793-XX RansPak

cascade and the 78809-00 ground resistor

assembly. The ground resistor assembly

is placed between the atomizer ground

connection and a true earth ground source.

NOTE

* See Note below.

1 3/8"-1 1/4"

(34-31 MM)

FRONT FERRULE

REAR FERRULE

NUT

78441-00

FERRULE ORIENTATION

Figure 17: Shroud Removal

Figure 14: 78842-00 In-Line

Resistor Assembly

Figure 16: 78441-00 Ferrule Orientation

Figure 15: 78809-00 Ground

Resistor Assembly

RMA-303 Indirect Charge - Maintenance

Ransburg

51

LN-9252-06.4

Advertising