RMA-303 Direct Charge - Maintenance

LN-9266-11.3

68

Bell Cup Removal

!

C A U T I O N

Failure to replace a damaged bell cup will

cause premature turbine failure. Warranty
will not be honored if the bell cup is dam-
aged.

N O T E

For removal of the 30mm or 55mm bell cups,
you must use bell cup wrench A11284-00. For
the 65mm bell cups you must use AA12061-00
bell cup wrench.

Bell Cup Wrenches

A11284-00 BELL CUP WRENCH

A12061-00 BELL CUP WRENCH

USE ON 30M AND 55MM BELL CUPS ONLY

USE ON 65MM BELL CUPS ONLY

To re-install a cup, position the wrench as
shown. Insert a torque wrench into the square
in the wrench to apply approximately 50-70
lbs•in (5.69-7.91 Nm) torque. Hold the cup
and tighten the torque wrench in a counter-
clockwise direction.

HOLD
BELL CUP

WITH ONE

HAND

CCW WITH
TORQUE
WRENCH

Bell Cup Installation

N O T E

There is a 3-inch center-to-center distance
between the bell cup and the 3/8-inch socket
square on the wrench. This distance must be
factored in when reading the proper torque on
the wrench.

Example: A desired true torque is desired
using a 9-inch effective length torque
wrench. Wrench offset is 3-inches.

L = 9-inches

TT = 50 lbs•in

E = 3-inches

DR = is dial reading.

DR = 50 (9) DR = 37.5 lbs•in
(9+3)